Automated loss of pulse detection on a consumer smartwatch
Out-of-hospital cardiac arrest is a time-sensitive emergency that requires prompt identification and intervention: sudden, unwitnessed cardiac arrest is nearly unsurvivable<sup>1-3</sup>. A cardinal sign of cardiac arrest is sudden loss of pulse<sup>4</sup>. Automated biosensor detection of unwitnessed cardiac arrest, and dispatch of medical assistance, may improve survivability given the substantial prognostic role of time<sup>3,5</sup>, but only if the false-positive burden on public emergency medical systems is minimized<sup>5-7</sup>. Here we show that a multimodal, machine learning-based algorithm on a smartwatch can reach performance thresholds making it deployable at a societal scale. First, using photoplethysmography, we show that wearable photoplethysmography measurements of peripheral pulselessness (induced through an arterial occlusion model) manifest similarly to pulselessness caused by a common cardiac arrest arrhythmia, ventricular fibrillation. On the basis of the similarity of the photoplethysmography signal (from ventricular fibrillation or arterial occlusion), we developed and validated a loss of pulse detection algorithm using data from peripheral pulselessness and free-living conditions. Following its development, we evaluated the end-to-end algorithm prospectively: there was 1 unintentional emergency call per 21.67 user-years across two prospective studies; the sensitivity was 67.23% (95% confidence interval of 64.32% to 70.05%) in a prospective arterial occlusion cardiac arrest simulation model. These results indicate an opportunity, deployable at scale, for wearable-based detection of sudden loss of pulse while minimizing societal costs of excess false detections<sup>7</sup>.
Authors
- Jack Phan (ORCID: https://orcid.org/0000-0001-5977-6004)
- Yun-Ling Lee
- Martin Wimmer
- Tajinder Gadh
- Anupam Pathak (ORCID: https://orcid.org/0000-0003-2225-8750)
- Pushmeet Kohli (ORCID: https://orcid.org/0000-0002-7466-7997)
- Bakul Patel (ORCID: https://orcid.org/0000-0002-1264-1783)
- E. L. Shi (ORCID: https://orcid.org/0000-0002-8506-7890)
- E. Silver (ORCID: https://orcid.org/0009-0005-9045-4528)
- S. Rajagopalan
- Ling Cai (ORCID: https://orcid.org/0000-0002-8592-5269)
- Thanh G. Phan (ORCID: https://orcid.org/0000-0003-3400-6323)
- Shelten Yuen
- Shwetak Patel (ORCID: https://orcid.org/0000-0002-6300-4389)
- Alistair Connell (ORCID: https://orcid.org/0000-0003-0318-1049)
- A Vasquez
- Kamal Shah (ORCID: https://orcid.org/0000-0003-2341-7688)
- Thomas D. Rea (ORCID: https://orcid.org/0000-0002-5143-9342)
- Jacqueline Baras Shreibati (ORCID: https://orcid.org/0000-0002-1410-9432)
- Jacob E. Sunshine (ORCID: https://orcid.org/0000-0001-9133-6922)
- Shakuntala Chhabra (ORCID: https://orcid.org/0000-0003-1994-3474)
- David P Miller (ORCID: https://orcid.org/0000-0003-2947-152X)
- Yiwen Chen (ORCID: https://orcid.org/0000-0003-2149-6466)
- Anran Wang (ORCID: https://orcid.org/0000-0003-1204-1785)
- Daniel McDuff (ORCID: https://orcid.org/0000-0001-7313-0082)
- Mark Malhotra (ORCID: https://orcid.org/0009-0009-0334-7759)
- Cary Fox
- Jim Taylor
- Beszel Hawkins
- Dinesh Puppala
- Pramod Rudrapatna
- Marc Stogaitis
- Jitender Munjal
- Anthony Stange
- Enxun Wei
- Tracy Giest
Institutions
- Google (United States) (US)
- Public Health – Seattle & King County (US)
- University of Washington (US)
- Arizona Heart Hospital (US)
- Cancer Research And Biostatistics (US)
- Google (United Kingdom) (GB)
- Baylor Jack and Jane Hamilton Heart and Vascular Hospital (US)
Publication Details
- Journal
- Nature
- Published
- 2025-02-26
- DOI
- https://doi.org/10.1038/s41586-025-08810-9
- Citations
- 25
- Primary Topic
- Power Line Communications and Noise
- Type
- article
- Field-Weighted Citation Impact
- 18.26