CH4, C2H6, and C2H4 Multi-Gas Sensing Based on Mid-Infrared Spectroscopy and SVM Algorithm

A multi-gas sensing system based on mid-infrared spectral absorption was developed for the detection of CH<sub>4</sub>, C<sub>2</sub>H<sub>6</sub>, and C<sub>2</sub>H<sub>4</sub>. The system utilized a broadband infrared source, a hollow waveguide (HWG) absorption cell, and a tunable Fabry-Pérot (FP) detector. The limits of detection (LODs) of CH<sub>4</sub>, C<sub>2</sub>H<sub>6</sub>, and C<sub>2</sub>H<sub>4</sub> were 7.33 ppm, 2.13 ppm, and 8.09 ppm, respectively. For multi-gas measurements, the support vector machine (SVM) algorithm model was employed to calculate the concentration of each component. The root mean square error of prediction (RMSEP) values for CH<sub>4</sub>, C<sub>2</sub>H<sub>6</sub>, and C<sub>2</sub>H<sub>4</sub> were 15.91 ppm (1.26%), 1.64 ppm (0.57%), and 6.95 ppm (0.55%), respectively. The generation of stimulated absorption spectra of mixed gases was realized, and the sample selection of measurement for accurate concentration calculation of each gas was optimized. The system proposed in this work provides a simple, miniaturized, and cost-effective solution for multi-gas sensing.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-02-26
DOI
https://doi.org/10.3390/s25051427
Citations
3
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
2.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CH4, C2H6, and C2H4 Multi-Gas Sensing Based on Mid-Infrared Spectroscopy and SVM Algorithm

Yi-Wei Shi, Xiaojie Su, Jiachen Jiang, Wenyuan Shao et al.
3 citations
Sensors
Spectroscopy and Laser Applications
2.27
article

CH4, C2H6, and C2H4 Multi-Gas Sensing Based on Mid-Infrared Spectroscopy and SVM Algorithm

Yi-Wei Shi, Xiaojie Su, Jiachen Jiang, Wenyuan Shao, Xiao-Song Zhu, Yunjiang Jia, Benlei Zhao, Limei Gao
article en
3 citations

Abstract

A multi-gas sensing system based on mid-infrared spectral absorption was developed for the detection of CH<sub>4</sub>, C<sub>2</sub>H<sub>6</sub>, and C<sub>2</sub>H<sub>4</sub>. The system utilized a broadband infrared source, a hollow waveguide (HWG) absorption cell, and a tunable Fabry-Pérot (FP) detector. The limits of detection (LODs) of CH<sub>4</sub>, C<sub>2</sub>H<sub>6</sub>, and C<sub>2</sub>H<sub>4</sub> were 7.33 ppm, 2.13 ppm, and 8.09 ppm, respectively. For multi-gas measurements, the support vector machine (SVM) algorithm model was employed to calculate the concentration of each component. The root mean square error of prediction (RMSEP) values for CH<sub>4</sub>, C<sub>2</sub>H<sub>6</sub>, and C<sub>2</sub>H<sub>4</sub> were 15.91 ppm (1.26%), 1.64 ppm (0.57%), and 6.95 ppm (0.55%), respectively. The generation of stimulated absorption spectra of mixed gases was realized, and the sample selection of measurement for accurate concentration calculation of each gas was optimized. The system proposed in this work provides a simple, miniaturized, and cost-effective solution for multi-gas sensing.

SensorsVol. 25(5)
Fudan University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 14%
Spectroscopy and Laser Applications
2.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.