Model-Based Control of Bioactuators with Feedback loop

For the industrial application of bioactuators, it is desirable to develop a method to precisely control skeletal muscles. In this study, a control method based on a muscle contraction model was proposed. This control method allows the skeletal muscles to exert an arbitrary contraction force, unlike conventional control that only switches between tension and relaxation. First, a method was developed to determine the voltage at which the skeletal muscles can exert an arbitrary contraction force based on the model by means of an optimization calculation. In addition to the model-based control, a feedback control system was also developed to reduce the errors. To evaluate the performance of the proposed method, the bioactuator made of skeletal muscle of toad was fabricated and validation experiments were conducted. The control voltage, that was calculated based on the contraction model, was applied to the bioactuator and the contraction force was controlled. As a result, the output of the actuator was able to follow the complex reference force. The results demonstrate the feasibility of precise control of the bioactuator.

Authors

Institutions

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/bmeicon64021.2024.10896336
Primary Topic
Control Systems in Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Model-Based Control of Bioactuators with Feedback loop

Wataru Hijikata, Mutsuki Hagiwara
Control Systems in Engineering
article

Model-Based Control of Bioactuators with Feedback loop

Wataru Hijikata, Mutsuki Hagiwara
article en

Abstract

For the industrial application of bioactuators, it is desirable to develop a method to precisely control skeletal muscles. In this study, a control method based on a muscle contraction model was proposed. This control method allows the skeletal muscles to exert an arbitrary contraction force, unlike conventional control that only switches between tension and relaxation. First, a method was developed to determine the voltage at which the skeletal muscles can exert an arbitrary contraction force based on the model by means of an optimization calculation. In addition to the model-based control, a feedback control system was also developed to reduce the errors. To evaluate the performance of the proposed method, the bioactuator made of skeletal muscle of toad was fabricated and validation experiments were conducted. The control voltage, that was calculated based on the contraction model, was applied to the bioactuator and the contraction force was controlled. As a result, the output of the actuator was able to follow the complex reference force. The results demonstrate the feasibility of precise control of the bioactuator.

Tokyo Institute of Technology (JP)
Affordable and clean energy
Openalex Percentile: Top 72%
Control Systems in Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.