The Study of a New Tethering Device on the Biomechanics of Short-Segment Fusion in the Lumbar Spine: A Finite Element Analysis

This study focused on the feasibility and effects of a new tethering device with various configuration parameters on short-segment fusion of the lumbar spine. A finite element model of the human lumbar spine (L1-L5) was used to simulate posterior lumbar interbody fusion (PLIF) with and without the new tethering device across the conventional instrumentation. The results were calculated in terms of range of motion (ROM), intradiscal pressure (IDP), and facet joint force (FJF), which are biomechanical factors related to adjacent segment disease (ASD). The results show that the new tehthering device has potential to improve the biomechanical factor when compare to standard PLIF. The finding in this study will be helpful to understand the behavior of tethering device and optimal configuration for most effective clinical result.

Authors

Institutions

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/bmeicon64021.2024.10896302
Citations
1
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Study of a New Tethering Device on the Biomechanics of Short-Segment Fusion in the Lumbar Spine: A Finite Element Analysis

Saran Keeratihattayakorn, Worawat Limthongkul, Chedtha Puncreobutr, Khanathip Jitpakdee et al.
1 citations
Medical Imaging and Analysis
0.18
article

The Study of a New Tethering Device on the Biomechanics of Short-Segment Fusion in the Lumbar Spine: A Finite Element Analysis

Saran Keeratihattayakorn, Worawat Limthongkul, Chedtha Puncreobutr, Khanathip Jitpakdee, Natthaphat Viria
article en
1 citations

Abstract

This study focused on the feasibility and effects of a new tethering device with various configuration parameters on short-segment fusion of the lumbar spine. A finite element model of the human lumbar spine (L1-L5) was used to simulate posterior lumbar interbody fusion (PLIF) with and without the new tethering device across the conventional instrumentation. The results were calculated in terms of range of motion (ROM), intradiscal pressure (IDP), and facet joint force (FJF), which are biomechanical factors related to adjacent segment disease (ASD). The results show that the new tehthering device has potential to improve the biomechanical factor when compare to standard PLIF. The finding in this study will be helpful to understand the behavior of tethering device and optimal configuration for most effective clinical result.

Chulalongkorn University (TH)
Affordable and clean energy
Openalex Percentile: Top 49%
Medical Imaging and Analysis
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.