Design and Control of 2DoF Wearable Robot Arm for Rehabilitation

Robotic therapy is gaining more popularity because of its proven success in regaining upper extremity movements and loco-motor skills, especially in stroke patients. In this work, the development of a low cost 2 degrees of freedoms (DoF) wearable robot arm is presented. This robotic exoskeleton device is aimed at rehabilitation of upper extremity disabilities caused by stroke or other brain ailments. The robot arm allows for flexion-extension movements at the shoulder and elbow joints to assist in targeted therapy of these important upper limb articulations. Notably, the device boasts several design enhancements over its low cost predecessors. Problems with bulky design and power losses due to its own inertia, in particular, have been effectively addressed, resulting in a more streamlined and efficient system. In addition to design and manufacture, Sliding mode based Cartesian compliance control simulation of the devices and a real-time joint space PID control results are presented in this paper.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/icrai62391.2024.10894684
Citations
1
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Control of 2DoF Wearable Robot Arm for Rehabilitation

Sukhan Lee, Said Ghani Khan, Abbas Hasan, Muath AlHamri et al.
1 citations
Stroke Rehabilitation and Recovery
0.25
article

Design and Control of 2DoF Wearable Robot Arm for Rehabilitation

Sukhan Lee, Said Ghani Khan, Abbas Hasan, Muath AlHamri, Omar Firoz
article en
1 citations

Abstract

Robotic therapy is gaining more popularity because of its proven success in regaining upper extremity movements and loco-motor skills, especially in stroke patients. In this work, the development of a low cost 2 degrees of freedoms (DoF) wearable robot arm is presented. This robotic exoskeleton device is aimed at rehabilitation of upper extremity disabilities caused by stroke or other brain ailments. The robot arm allows for flexion-extension movements at the shoulder and elbow joints to assist in targeted therapy of these important upper limb articulations. Notably, the device boasts several design enhancements over its low cost predecessors. Problems with bulky design and power losses due to its own inertia, in particular, have been effectively addressed, resulting in a more streamlined and efficient system. In addition to design and manufacture, Sliding mode based Cartesian compliance control simulation of the devices and a real-time joint space PID control results are presented in this paper.

University of Bahrain (BH), Shaheed Benazir Bhutto University (PK)
Openalex Percentile: Top 35%
Stroke Rehabilitation and Recovery
0.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Control of 2DoF Wearable Robot Arm for Rehabilitation — Sukhan Lee, Said Ghani Khan, et al. · (2024) | TGRS Research Map | TGRS