Biomechanical Analysis of the Influence of Prosthesis Installation Parameters on Soft Tissue Tension in Elbow Joint Replacement

Elbow j oint replacement is an important method to restore elbow joint function of patients with severe elbow injuries. The installation parameters of the prosthesis greatly affect the capacity of the elbow joint, and the service life of the prosthesis. This article provides a reference for planning the installation position of the prosthesis by analyzing the impact of prosthesis installation parameters on related muscle forces. First, a biomechanical model including the humerus, ulna, and related muscles is established. Secondly, the elbow joint replacement surgery is simulated, and a skeletal-prosthesis-muscle combined simulation model is created. Finally, by simulating the deviation of the hinge center of the humeral prosthesis from the ideal center within the range of surgical error in actual operations, the muscle forces are calculated and the impact of prosthesis installation parameters on muscle forces is analyzed. The simulation results demonstrate the effects of minor misalignment during installation to the muscle forces and j oint reaction forces, providing quantitative references for surgical planning.

Authors

Institutions

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/bmeicon64021.2024.10896352
Primary Topic
Engineering Technology and Methodologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Analysis of the Influence of Prosthesis Installation Parameters on Soft Tissue Tension in Elbow Joint Replacement

Yangyu Luo, Xieyuan Jiang, Jian Chen, Teng Zhang et al.
Engineering Technology and Methodologies
article

Biomechanical Analysis of the Influence of Prosthesis Installation Parameters on Soft Tissue Tension in Elbow Joint Replacement

Yangyu Luo, Xieyuan Jiang, Jian Chen, Teng Zhang, Wei Han, Juan Wang
article en

Abstract

Elbow j oint replacement is an important method to restore elbow joint function of patients with severe elbow injuries. The installation parameters of the prosthesis greatly affect the capacity of the elbow joint, and the service life of the prosthesis. This article provides a reference for planning the installation position of the prosthesis by analyzing the impact of prosthesis installation parameters on related muscle forces. First, a biomechanical model including the humerus, ulna, and related muscles is established. Secondly, the elbow joint replacement surgery is simulated, and a skeletal-prosthesis-muscle combined simulation model is created. Finally, by simulating the deviation of the hinge center of the humeral prosthesis from the ideal center within the range of surgical error in actual operations, the muscle forces are calculated and the impact of prosthesis installation parameters on muscle forces is analyzed. The simulation results demonstrate the effects of minor misalignment during installation to the muscle forces and j oint reaction forces, providing quantitative references for surgical planning.

Chinese Academy of Sciences (CN), Peking University (CN), Beijing Jishuitan Hospital (CN), Shandong Institute of Automation (CN)
Openalex Percentile: Top 59%
Engineering Technology and Methodologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Biomechanical Analysis of the Influence of Prosthesis Installation Parameters on Soft Tissue Tension in Elbow Joint Replacement — Yangyu Luo, Xieyuan Jiang, et al. · (2024) | TGRS Research Map | TGRS