Detection of Silver(I) Ions by Ion-Imprinted SPR Sensors

In this study, Ag(I) ion-imprinted and nonimprinted (NIP) poly(hydroxyethyl methacrylate-methacryloylamidocysteine) [poly(HEMA-MAC)] polimeric film-based surface plasmon resonance (SPR) sensors were prepared for the determination of silver ions (I) (Ag(I) ions). Atomic force microscopy (AFM) and contact angle measurements were used for the characterization of Ag(I) ion-imprinted and NIP SPR sensors. Kinetic studies are the limit of detection of 0.015 nM in the Ag(I) ions concentration range ranging from 0.5 to 1000 nM. When the selectivity of Ag(I) ion-imprinted SPR sensors was compared with the competing ions as lead (II) and copper (II) ions, it was shown that Ag(I) ions were 2.74 times and 7.04 times more selective than lead (II) and copper (II) ions, respectively. The reusability and shelf life of the developed SPR sensor has shown a decrease of 12.08% compared to kinetic analyses performed after 6 months. In addition, the determination of Ag(I) ions from real water samples was made using both SPR sensor and atomic absorption spectroscopy (AAS).

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-02-26
DOI
https://doi.org/10.1109/jsen.2025.3543283
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Silver(I) Ions by Ion-Imprinted SPR Sensors

Adi̇l Deni̇zli̇, Duygu Çimen, Mitra Jalilzadeh
1 citations
IEEE Sensors Journal
Analytical chemistry methods development
0.75
article

Detection of Silver(I) Ions by Ion-Imprinted SPR Sensors

Adi̇l Deni̇zli̇, Duygu Çimen, Mitra Jalilzadeh
article en
1 citations

Abstract

In this study, Ag(I) ion-imprinted and nonimprinted (NIP) poly(hydroxyethyl methacrylate-methacryloylamidocysteine) [poly(HEMA-MAC)] polimeric film-based surface plasmon resonance (SPR) sensors were prepared for the determination of silver ions (I) (Ag(I) ions). Atomic force microscopy (AFM) and contact angle measurements were used for the characterization of Ag(I) ion-imprinted and NIP SPR sensors. Kinetic studies are the limit of detection of 0.015 nM in the Ag(I) ions concentration range ranging from 0.5 to 1000 nM. When the selectivity of Ag(I) ion-imprinted SPR sensors was compared with the competing ions as lead (II) and copper (II) ions, it was shown that Ag(I) ions were 2.74 times and 7.04 times more selective than lead (II) and copper (II) ions, respectively. The reusability and shelf life of the developed SPR sensor has shown a decrease of 12.08% compared to kinetic analyses performed after 6 months. In addition, the determination of Ag(I) ions from real water samples was made using both SPR sensor and atomic absorption spectroscopy (AAS).

IEEE Sensors JournalVol. 25(7)
Hacettepe University (TR)
Openalex Percentile: Top 36%
Analytical chemistry methods development
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.