Linearized Temperature-Compensated Hydrogen Sensing With Partially Pd-Alloy-Coated π-FBGs

Intraspectral referencing comprises a single-sensor solution, where simultaneous measurements of hydrogen concentration and temperature are achieved within a single, partially palladium-coated <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\pi $ </tex-math></inline-formula>-phase-shifted fiber Bragg grating (FBG). Highly localized, hydrogen-induced strain sections provoke the notch and the envelope of the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\pi $ </tex-math></inline-formula>-FBG spectrum to yield different hydrogen responses, while temperature affects both features almost identically. The precise temperature compensation in sub-Kelvin ranges was used to characterize the functional layer in the range of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$20~^{\circ }$ </tex-math></inline-formula>C–<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$50~^{\circ }$ </tex-math></inline-formula>C and at 250–20 000 ppm H2 in N2. Upon initial hydrogen exposure after fabrication, a gradually decreasing sensitivity drift was observed, which relaxed and stabilized after sufficiently long initialization with hydrogen. The desorption consisted of at least two processes, a fast desorption when large amounts of hydrogen are present in the nanofilm, followed by a notably slow desorption (~5 h) until the baseline was recovered. A zero-point referenced calibration scheme of the PTFE-capped Pd91:Ni09 fiber optic hydrogen sensor revealed a strong nonlinear response, especially at low concentrations <1000 ppm. This required linearization, which led to effective decoupling of the temperature cross-sensitivity through iterative data processing. Decoupled concentrations and temperatures show a lower detection limit of 250 ppm, a significant enhancement in baseline stability, and time constants of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${t}_{{90}} =19$ </tex-math></inline-formula> s for ab- and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${t}_{{10}} =18$ </tex-math></inline-formula> s for desorption. This work paves the way for both practical applications of fiber optic H2 sensors and fundamental research in Pd nanofilm engineering.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-02-26
DOI
https://doi.org/10.1109/jsen.2025.3541292
Citations
1
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Linearized Temperature-Compensated Hydrogen Sensing With Partially Pd-Alloy-Coated π-FBGs

Philipp C. Schmid, Fan Zhang, Fabian Buchfellner, Andrea Stadler et al.
1 citations
IEEE Sensors Journal
Advanced Fiber Optic Sensors
0.73
article

Linearized Temperature-Compensated Hydrogen Sensing With Partially Pd-Alloy-Coated π-FBGs

Philipp C. Schmid, Fan Zhang, Fabian Buchfellner, Andrea Stadler, Alexander W. Koch, Qiang Bian, Alexander Roehrl, Minghong Yang, Johannes Roths
article en
1 citations

Abstract

Intraspectral referencing comprises a single-sensor solution, where simultaneous measurements of hydrogen concentration and temperature are achieved within a single, partially palladium-coated <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\pi $ </tex-math></inline-formula>-phase-shifted fiber Bragg grating (FBG). Highly localized, hydrogen-induced strain sections provoke the notch and the envelope of the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\pi $ </tex-math></inline-formula>-FBG spectrum to yield different hydrogen responses, while temperature affects both features almost identically. The precise temperature compensation in sub-Kelvin ranges was used to characterize the functional layer in the range of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$20~^{\circ }$ </tex-math></inline-formula>C–<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$50~^{\circ }$ </tex-math></inline-formula>C and at 250–20 000 ppm H2 in N2. Upon initial hydrogen exposure after fabrication, a gradually decreasing sensitivity drift was observed, which relaxed and stabilized after sufficiently long initialization with hydrogen. The desorption consisted of at least two processes, a fast desorption when large amounts of hydrogen are present in the nanofilm, followed by a notably slow desorption (~5 h) until the baseline was recovered. A zero-point referenced calibration scheme of the PTFE-capped Pd91:Ni09 fiber optic hydrogen sensor revealed a strong nonlinear response, especially at low concentrations <1000 ppm. This required linearization, which led to effective decoupling of the temperature cross-sensitivity through iterative data processing. Decoupled concentrations and temperatures show a lower detection limit of 250 ppm, a significant enhancement in baseline stability, and time constants of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${t}_{{90}} =19$ </tex-math></inline-formula> s for ab- and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${t}_{{10}} =18$ </tex-math></inline-formula> s for desorption. This work paves the way for both practical applications of fiber optic H2 sensors and fundamental research in Pd nanofilm engineering.

IEEE Sensors JournalVol. 25(8)
National University of Defense Technology (CN), Munich University of Applied Sciences (DE), Wuhan University of Technology (CN), Technical University of Munich (DE)
Deutsche Forschungsgemeinschaft, National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 31%
Advanced Fiber Optic Sensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.