Comparison of Various <scp>GAN</scp>‐Based Bone Suppression Imaging for High‐Accurate Markerless Motion Tracking of Lung Tumors in <scp>CyberKnife</scp> Treatment

Stereotactic body radiation therapy (SBRT) is a highly effective treatment for lung cancer; however, challenges arise from tumor motion induced by respiration. The CyberKnife system, incorporating both fiducial-based and fiducial-free tracking modalities, aims to mitigate these challenges, yet tumor recognition can be compromised by overlapping bone structures. This study introduces a novel bone suppression imaging technique for kilovolt X-ray imaging using generative adversarial networks (GANs) to enhance tumor tracking in SBRT by reducing interference from bony structures. Computed tomography (CT) images, both with and without bone structures, were generated using a four-dimensional extended cardiac-torso phantom (XCAT phantom) across 56 cases. X-ray projections were captured from left and right oblique 45° angles and divided into nine segments, producing 1120 images. These images were processed through six pre-trained GAN models-CycleGAN, DualGAN, CUT, FastCUT, DCLGAN, and SimDCL-yielding bone-suppressed images on the XCAT phantom (BSI<sub>phantom</sub>). The resulting images were evaluated against bone-shadow-free images using structural similarity index measure (SSIM), peak signal-to-noise ratio (PSNR), and Frechet inception distance (FID). Additionally, bone-suppressed images (BSI<sub>patient</sub>) were derived from 1000 non-simulated patient images. BSI<sub>phantom</sub> images achieved SSIM and PSNR values of 0.96 ± 0.02 and 36.93 ± 3.93, respectively. SimDCL exhibited optimal performance with an FID score of 68.93, indicative of superior image generation quality. This GAN-based bone suppression imaging technique markedly improved image recognition and refined dynamic tumor tracking, enhancing the accuracy and efficacy of SBRT.

Authors

Institutions

Publication Details

Journal
Thoracic Cancer
Published
2025-02-01
DOI
https://doi.org/10.1111/1759-7714.70014
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Various GAN‐Based Bone Suppression Imaging for High‐Accurate Markerless Motion Tracking of Lung Tumors in CyberKnife Treatment

Koji Mochizuki, Zennosuke Mochizuki, Hikaru Nemoto, Masahide Saito et al.
Thoracic Cancer
Medical Imaging Techniques and Applications
article

Comparison of Various GAN‐Based Bone Suppression Imaging for High‐Accurate Markerless Motion Tracking of Lung Tumors in CyberKnife Treatment

Koji Mochizuki, Zennosuke Mochizuki, Hikaru Nemoto, Masahide Saito, Hiroshi Onishi, Toshihiro Suzuki, Hiroshi Takahashi
article en

Abstract

Stereotactic body radiation therapy (SBRT) is a highly effective treatment for lung cancer; however, challenges arise from tumor motion induced by respiration. The CyberKnife system, incorporating both fiducial-based and fiducial-free tracking modalities, aims to mitigate these challenges, yet tumor recognition can be compromised by overlapping bone structures. This study introduces a novel bone suppression imaging technique for kilovolt X-ray imaging using generative adversarial networks (GANs) to enhance tumor tracking in SBRT by reducing interference from bony structures. Computed tomography (CT) images, both with and without bone structures, were generated using a four-dimensional extended cardiac-torso phantom (XCAT phantom) across 56 cases. X-ray projections were captured from left and right oblique 45° angles and divided into nine segments, producing 1120 images. These images were processed through six pre-trained GAN models-CycleGAN, DualGAN, CUT, FastCUT, DCLGAN, and SimDCL-yielding bone-suppressed images on the XCAT phantom (BSI<sub>phantom</sub>). The resulting images were evaluated against bone-shadow-free images using structural similarity index measure (SSIM), peak signal-to-noise ratio (PSNR), and Frechet inception distance (FID). Additionally, bone-suppressed images (BSI<sub>patient</sub>) were derived from 1000 non-simulated patient images. BSI<sub>phantom</sub> images achieved SSIM and PSNR values of 0.96 ± 0.02 and 36.93 ± 3.93, respectively. SimDCL exhibited optimal performance with an FID score of 68.93, indicative of superior image generation quality. This GAN-based bone suppression imaging technique markedly improved image recognition and refined dynamic tumor tracking, enhancing the accuracy and efficacy of SBRT.

Thoracic CancerVol. 16(4)
Kasugai Municipal Hospital (JP), University of Yamanashi (JP)
Openalex Percentile: Top 95%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies