Influence of DC Harmonic Voltages on Partial Discharge Behaviour in SF<sub>6</sub> Alternatives Gases

The nature of rectifier station operation can introduce harmonics into electrical systems. Understanding the impact of these harmonics on the insulation properties of gases in gas-insulated systems, particularly regarding partial discharge generation and inception voltages in the assessment SF<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf> alternatives. This study examined the behaviour of partial discharges under conditions of DC ripple compared to filtered DC voltage, evaluating their dielectric effectiveness in DC electrical systems susceptible to abnormal harmonic contents. By analysing the results, this research explored the performance of three alternative gases to SF<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf> under the effects of ripple content. Conducted through systematic comparison, the outcomes of this research could aid in understanding the behavior of partial discharges under direct current conditions. It might be beneficial for system operators further evaluating the impact of these conditions to choose the SF<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf> alternatives more carefully.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/upec61344.2024.10892567
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of DC Harmonic Voltages on Partial Discharge Behaviour in SF6 Alternatives Gases

Michail Michelarakis, K.‐L. Zhang, Alistair Reid, A. Haddad
1 citations
High voltage insulation and dielectric phenomena
0.12
article

Influence of DC Harmonic Voltages on Partial Discharge Behaviour in SF6 Alternatives Gases

Michail Michelarakis, K.‐L. Zhang, Alistair Reid, A. Haddad
article en
1 citations

Abstract

The nature of rectifier station operation can introduce harmonics into electrical systems. Understanding the impact of these harmonics on the insulation properties of gases in gas-insulated systems, particularly regarding partial discharge generation and inception voltages in the assessment SF<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf> alternatives. This study examined the behaviour of partial discharges under conditions of DC ripple compared to filtered DC voltage, evaluating their dielectric effectiveness in DC electrical systems susceptible to abnormal harmonic contents. By analysing the results, this research explored the performance of three alternative gases to SF<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf> under the effects of ripple content. Conducted through systematic comparison, the outcomes of this research could aid in understanding the behavior of partial discharges under direct current conditions. It might be beneficial for system operators further evaluating the impact of these conditions to choose the SF<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf> alternatives more carefully.

Cardiff University (GB)
Affordable and clean energy
Openalex Percentile: Top 56%
High voltage insulation and dielectric phenomena
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.