Bismuth Silicon Oxide Receiver for Low Frequency Ultrasound from a Liquid Metal Transducer with Carbon Nanofibers

Advanced structures like nuclear and solar power plants produce energy in extreme environments at high temperatures, or with strong radiation, and thus require advanced sensors for monitoring. Robust and durable materials are required for effective structural monitoring. The integrity of structures is often monitored using ultrasound, generated by piezoelectric materials or lasers. The baseline test of Bismuth Silicon Oxide (Bi<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">12</inf>SiO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">20</inf>; BSO) as a transmitter and receiver was promising for high sensitivity and accuracy. In a previous work, our lab used a combination of liquid Fields metal (Bi-In-Sn; FM) and carbon nanofibers (~ 25μm thick; CNF) to produce low frequency laser induced ultrasound at roughly 200 kHz. In this work, a BSO sensor was used to receive ultrasound from 1) a FM-CNF laser ultrasound transmitter, and 2) a BSO transmitter. The CNF's were used to increase the optical absorbance of the FM transducer, which normally has low optical absorbance (<20%), and thus increase the overall photoacoustic efficiency. The CNF's have high optical absorbance and high thermal diffusivity, ideal for dispersing thermal energy converted from the laser light into heat. This results in thermal expansion from the FM which generates and acoustic wave. Ultimately, pulsed laser light is used with the FM-CNF combination to produce ultrasound. A comparison was made to determine which transducer was more effective at generating ultrasound at ~200 kHz. The FM-CNF and BSO results were comparable, situated at a distance of 420 mm and 360 mm from the receiver, producing signals of 53.6 mV<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">pp</inf> and 43 mV<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">pp</inf>, respectively.

Authors

Institutions

Publication Details

Published
2024-10-21
DOI
https://doi.org/10.1109/nmdc58214.2024.10894022
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bismuth Silicon Oxide Receiver for Low Frequency Ultrasound from a Liquid Metal Transducer with Carbon Nanofibers

Tiegang Fang, Xiaoning Jiang, Kaushik Nonavinakere Vinod, Fapeng Yu et al.
Ultrasound Imaging and Elastography
article

Bismuth Silicon Oxide Receiver for Low Frequency Ultrasound from a Liquid Metal Transducer with Carbon Nanofibers

Tiegang Fang, Xiaoning Jiang, Kaushik Nonavinakere Vinod, Fapeng Yu, Nicholas Garcia, Huaiyu Wu, Shujun J. Zhang, Quinn Fonner
article en

Abstract

Advanced structures like nuclear and solar power plants produce energy in extreme environments at high temperatures, or with strong radiation, and thus require advanced sensors for monitoring. Robust and durable materials are required for effective structural monitoring. The integrity of structures is often monitored using ultrasound, generated by piezoelectric materials or lasers. The baseline test of Bismuth Silicon Oxide (Bi<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">12</inf>SiO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">20</inf>; BSO) as a transmitter and receiver was promising for high sensitivity and accuracy. In a previous work, our lab used a combination of liquid Fields metal (Bi-In-Sn; FM) and carbon nanofibers (~ 25μm thick; CNF) to produce low frequency laser induced ultrasound at roughly 200 kHz. In this work, a BSO sensor was used to receive ultrasound from 1) a FM-CNF laser ultrasound transmitter, and 2) a BSO transmitter. The CNF's were used to increase the optical absorbance of the FM transducer, which normally has low optical absorbance (<20%), and thus increase the overall photoacoustic efficiency. The CNF's have high optical absorbance and high thermal diffusivity, ideal for dispersing thermal energy converted from the laser light into heat. This results in thermal expansion from the FM which generates and acoustic wave. Ultimately, pulsed laser light is used with the FM-CNF combination to produce ultrasound. A comparison was made to determine which transducer was more effective at generating ultrasound at ~200 kHz. The FM-CNF and BSO results were comparable, situated at a distance of 420 mm and 360 mm from the receiver, producing signals of 53.6 mV<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">pp</inf> and 43 mV<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">pp</inf>, respectively.

North Carolina State University (US), Shandong University (CN), University of Wollongong (AU), State Key Laboratory of Crystal Materials
Openalex Percentile: Top 57%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.