Contribution to the Measurement of HVDC Partial Discharges Inception Voltage of Natural Gases

In this paper, a comparative study of DC Partial Discharge Inception Voltage (PDIV) performances are presented. The goal is to determine the role of breakdown ageing on the DC PDIV. Two natural gases were used: CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> and Dry (Synthetic) Air in a range of pressure 1 - 6 bar. A reduced-scale GIL vessel is used with a grounded pin. The PDIVs are measured before breakdown ageing and after breakdown ageing. The results showed that PDIVs levels of aged gases are lower than PDIV of non-aged gases. GCMS analysis showed that aged gases contain some traces of decomposition products provoked by arcing and interaction with the solid insulation material (PTFE). On the other hand, traces of arcing impact at the inner electrode are observed and affect the PDIVs levels.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/upec61344.2024.10892503
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contribution to the Measurement of HVDC Partial Discharges Inception Voltage of Natural Gases

Mohammed El Amine Slama, Michail Michelarakis, Meirion Hills, A. Haddad et al.
High voltage insulation and dielectric phenomena
article

Contribution to the Measurement of HVDC Partial Discharges Inception Voltage of Natural Gases

Mohammed El Amine Slama, Michail Michelarakis, Meirion Hills, A. Haddad, C. Stone
article en

Abstract

In this paper, a comparative study of DC Partial Discharge Inception Voltage (PDIV) performances are presented. The goal is to determine the role of breakdown ageing on the DC PDIV. Two natural gases were used: CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> and Dry (Synthetic) Air in a range of pressure 1 - 6 bar. A reduced-scale GIL vessel is used with a grounded pin. The PDIVs are measured before breakdown ageing and after breakdown ageing. The results showed that PDIVs levels of aged gases are lower than PDIV of non-aged gases. GCMS analysis showed that aged gases contain some traces of decomposition products provoked by arcing and interaction with the solid insulation material (PTFE). On the other hand, traces of arcing impact at the inner electrode are observed and affect the PDIVs levels.

Cardiff University (GB)
Openalex Percentile: Top 83%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.