Surface Leakage Current Analysis of a 500 kV DC Voltage Divider under Natural Environmental Influences

In this work, a SMD-based 500 kV DC voltage divider is investigated for possible load scenarios of HVDC installations. For this purpose, the leakage current across the surface of the voltage divider's insulation is measured using long-term measurements over several days and short-term measurements with different voltage levels, with consideration of the weather situation. The measured leakage currents are analyzed quantitatively in order to evaluate the influence of the environmental conditions. Another aspect of the analyses are sequential voltage ramping tests with different voltage levels in order to investigate the effects on the insulation during the ramp-up and ramp-down of voltage levels. The results show that the leakage current on a wetted surface reacts significantly to changes in high relative humidity. Furthermore, additional alternating loads to the DC voltage, as is the case with ramp-up and ramp-down voltage changes, have a recognizable influence on the value of the leakage current.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/upec61344.2024.10892499
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surface Leakage Current Analysis of a 500 kV DC Voltage Divider under Natural Environmental Influences

Julian Hanusrichter, Frank Jenau, Tobias Kuhnke
HVDC Systems and Fault Protection
article

Surface Leakage Current Analysis of a 500 kV DC Voltage Divider under Natural Environmental Influences

Julian Hanusrichter, Frank Jenau, Tobias Kuhnke
article en

Abstract

In this work, a SMD-based 500 kV DC voltage divider is investigated for possible load scenarios of HVDC installations. For this purpose, the leakage current across the surface of the voltage divider's insulation is measured using long-term measurements over several days and short-term measurements with different voltage levels, with consideration of the weather situation. The measured leakage currents are analyzed quantitatively in order to evaluate the influence of the environmental conditions. Another aspect of the analyses are sequential voltage ramping tests with different voltage levels in order to investigate the effects on the insulation during the ramp-up and ramp-down of voltage levels. The results show that the leakage current on a wetted surface reacts significantly to changes in high relative humidity. Furthermore, additional alternating loads to the DC voltage, as is the case with ramp-up and ramp-down voltage changes, have a recognizable influence on the value of the leakage current.

TU Dortmund University (DE)
Life in Land
Openalex Percentile: Top 74%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.