Effect of Ground Rods Position on Current Distribution in Ground Grid under Transient Current

This paper examines current distribution in a buried ground grid under variable frequency and impulse currents, highlighting the significant importance of current injection points and the effect of ground rod positioning. Experimental results on impulse studies are considered, followed by CDEGS simulations to discuss the findings. For grids without rods, the results show that localized soil conditions impact current dissipation, affecting earth potential rise during lightning strikes. While corner-connected vertical rods contribute to current dissipation, their effectiveness diminishes when placed farther from the injection point, raising questions about their practical application for improved transient performance. Additionally, the selection of ground rod positions has a significant effect on current distribution in the grid branches, especially under high-frequency and transient conditions.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/upec61344.2024.10892423
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Ground Rods Position on Current Distribution in Ground Grid under Transient Current

S. Mousa, Omar Kherif, N. Harid, ASSED NAKED HADDAD et al.
High-Voltage Power Transmission Systems
article

Effect of Ground Rods Position on Current Distribution in Ground Grid under Transient Current

S. Mousa, Omar Kherif, N. Harid, ASSED NAKED HADDAD, Stephen Robson, H. Griffiths, D. Thorpe
article en

Abstract

This paper examines current distribution in a buried ground grid under variable frequency and impulse currents, highlighting the significant importance of current injection points and the effect of ground rod positioning. Experimental results on impulse studies are considered, followed by CDEGS simulations to discuss the findings. For grids without rods, the results show that localized soil conditions impact current dissipation, affecting earth potential rise during lightning strikes. While corner-connected vertical rods contribute to current dissipation, their effectiveness diminishes when placed farther from the injection point, raising questions about their practical application for improved transient performance. Additionally, the selection of ground rod positions has a significant effect on current distribution in the grid branches, especially under high-frequency and transient conditions.

Khalifa University of Science and Technology (AE), Cardiff University (GB)
Climate action
Openalex Percentile: Top 74%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.