Investigation of the effect of boric acid concentration on neutron reflection coefficient

In this study, the neutron reflection coefficient from boric acid solutions was measured at ten concentrations from 1.6 g/L to 16 g/L and thicknesses from 1 cm to 15 cm. The neutron-reflecting solutions were prepared using pure water with a conductivity of 0.08 μS/cm and boric acid produced by AppliChem, Germany. A 5.2 Ci neutron source and a BF 3 neutron detector housed inside a cylindrical cadmium shield with a thickness of 1.45 cm were used to measure the intensity of neutrons reflected from the solutions. At a concentration of 16 g/L, the saturation thickness of solution for neutron reflection was found to be 14 cm. The experimental results also indicated that the solution of 1.6 g/L boric acid concentration reduces neutron reflection by 5.2 %. Also this value was calculated using the diffusion equation about 5.3 %. Additionally, for a concentration of 16 g/L the percentage reduction in neutron reflection, obtained from both measurements and albedo calculations using the diffusion equation, were 33.1 % and 28.6 %, respectively.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2025-02-26
DOI
https://doi.org/10.1016/j.net.2025.103564
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the effect of boric acid concentration on neutron reflection coefficient

Farhad Zolfagharpour, S. Azimkhani, Farhad Karimi
Nuclear Engineering and Technology
Nuclear Physics and Applications
article

Investigation of the effect of boric acid concentration on neutron reflection coefficient

Farhad Zolfagharpour, S. Azimkhani, Farhad Karimi
article en

Abstract

In this study, the neutron reflection coefficient from boric acid solutions was measured at ten concentrations from 1.6 g/L to 16 g/L and thicknesses from 1 cm to 15 cm. The neutron-reflecting solutions were prepared using pure water with a conductivity of 0.08 μS/cm and boric acid produced by AppliChem, Germany. A 5.2 Ci neutron source and a BF 3 neutron detector housed inside a cylindrical cadmium shield with a thickness of 1.45 cm were used to measure the intensity of neutrons reflected from the solutions. At a concentration of 16 g/L, the saturation thickness of solution for neutron reflection was found to be 14 cm. The experimental results also indicated that the solution of 1.6 g/L boric acid concentration reduces neutron reflection by 5.2 %. Also this value was calculated using the diffusion equation about 5.3 %. Additionally, for a concentration of 16 g/L the percentage reduction in neutron reflection, obtained from both measurements and albedo calculations using the diffusion equation, were 33.1 % and 28.6 %, respectively.

Nuclear Engineering and TechnologyVol. 57(8)
University of Mohaghegh Ardabili (IR)
Openalex Percentile: Top 96%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.