Image-Guided FLASH ProtonTherapy. A dream? Naivety?Arrogance? Or a Necessity?

<b>Objective:</b> The in-vivo therapy guidance by imaging and dosimetry of proton irradiations, generically known as proton range verification, are some of the most underinvested aspects of radiation oncology. They trail behind other advances in radiation therapy due to the scarcity of sensitive instruments compounded by the lack of treatment protocols for precision monitoring of effects of beam radiation. This is despite that such measurements may dramatically enhance the treatment accuracy and lower the postradiation toxicity, thus improving the entire outcome of cancer therapy. <br><b>Methods:</b> In this contribution, we focus on the motivation of designing and building of an in-beam time-of-flight (ToF) positron-emission-tomography (PET) scanner with the depth-of-interaction (DoI) capability for high sensitivity and improved fidelity of imaging. A scanner could be augmented with a tungsten collimator that would enable prompt-gamma imaging (PGI) via single-photon emission computed tomography (SPECT) technique. <br><b>Results:</b> We present selected results of our pre-clinical experiments with a FLASH proton beam and discuss other related ideas towards improving and expanding the use of PET/PGI/SPECT detectors for proton therapy. A scanner provides an access to data during the spill and past the spill permitting to capture the beam interaction and kinetic monitoring of its effect thus allowing a thorough assessment of each irradiation.<br><b>Conclusions:</b> A novel scanner for multiple modalities can substantially improve the treatment precision of proton therapy leading to less toxic outcome of irradiations. Using it in the FLASH modality would additionally expand the patient reach of proton therapy.

Authors

Institutions

Publication Details

Journal
Bio-Algorithms and Med-Systems
Published
2024-12-11
DOI
https://doi.org/10.5604/01.3001.0054.8930
Citations
2
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Image-Guided FLASH ProtonTherapy. A dream? Naivety?Arrogance? Or a Necessity?

K. Lang
2 citations
Bio-Algorithms and Med-Systems
Radiation Therapy and Dosimetry
0.84
article

Image-Guided FLASH ProtonTherapy. A dream? Naivety?Arrogance? Or a Necessity?

K. Lang
article en
2 citations

Abstract

<b>Objective:</b> The in-vivo therapy guidance by imaging and dosimetry of proton irradiations, generically known as proton range verification, are some of the most underinvested aspects of radiation oncology. They trail behind other advances in radiation therapy due to the scarcity of sensitive instruments compounded by the lack of treatment protocols for precision monitoring of effects of beam radiation. This is despite that such measurements may dramatically enhance the treatment accuracy and lower the postradiation toxicity, thus improving the entire outcome of cancer therapy. <br><b>Methods:</b> In this contribution, we focus on the motivation of designing and building of an in-beam time-of-flight (ToF) positron-emission-tomography (PET) scanner with the depth-of-interaction (DoI) capability for high sensitivity and improved fidelity of imaging. A scanner could be augmented with a tungsten collimator that would enable prompt-gamma imaging (PGI) via single-photon emission computed tomography (SPECT) technique. <br><b>Results:</b> We present selected results of our pre-clinical experiments with a FLASH proton beam and discuss other related ideas towards improving and expanding the use of PET/PGI/SPECT detectors for proton therapy. A scanner provides an access to data during the spill and past the spill permitting to capture the beam interaction and kinetic monitoring of its effect thus allowing a thorough assessment of each irradiation.<br><b>Conclusions:</b> A novel scanner for multiple modalities can substantially improve the treatment precision of proton therapy leading to less toxic outcome of irradiations. Using it in the FLASH modality would additionally expand the patient reach of proton therapy.

Bio-Algorithms and Med-SystemsVol. 20(Special Issue)
The University of Texas at Austin (US)
Openalex Percentile: Top 22%
Radiation Therapy and Dosimetry
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.