Impact of packing configurations and thickness on the performance of filtration humidifier

• Celdek 7090 packing outperformed both Celdek 5090 and corrugated packings. • The COP and efficiency were found as 2.15 and 85.57 %, respectively. • Packing using grey water releases more contaminants than when using salt water. • Greater packing thickness enhances humidification performance and reduces pollution. • Increased wettability improves overall humidification efficiency. The current study centers on the design and fabrication of a direct-type evaporative cooling unit utilizing gray and salt water as working fluids. Three distinct packing configurations—Celdek 7090, Celdek 5090, and corrugated—were incorporated into a counterflow humidifier system to evaluate their performance in both humidification and water filtration. The air Reynolds number varied from 32,596 to 58,674, with performance metrics assessed across different packing configurations, wettabilities, and fluids. The system achieved an evaporation rate of 0.1158 g/s, a coefficient of performance (COP) of 2.15, a humidification efficiency of 85.57 %, and a cooling effect of 251.35 W, with Celdek 7090 outperforming the other configurations when paired with salt water. As packing thickness increased for gray water, CO 2 levels decreased by 5.83 %, 6.19 %, and 6.55 % for the Corrugated, Celdek 5090, and Celdek 7090 packings, respectively. Formaldehyde (HCHO) concentrations were reduced by 38.09 %, 40 %, and 38.88 %, while total volatile organic compounds (TVOC) decreased by 21.73 %, 23.80 %, and 26.31 %. Pollution levels were found to rise with increasing Reynolds number, yet tests confirmed that the air leaving the system was of superior quality. Enhanced packing thickness not only improved humidification performance but also further reduced pollution levels.

Authors

Institutions

Publication Details

Journal
Energy and Built Environment
Published
2025-02-01
DOI
https://doi.org/10.1016/j.enbenv.2025.02.005
Citations
1
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of packing configurations and thickness on the performance of filtration humidifier

Shiva Kumar, Sampath Suranjan Salins, S.V. Kota Reddy
1 citations
Energy and Built Environment
Adsorption and Cooling Systems
0.71
article

Impact of packing configurations and thickness on the performance of filtration humidifier

Shiva Kumar, Sampath Suranjan Salins, S.V. Kota Reddy
article en
1 citations

Abstract

• Celdek 7090 packing outperformed both Celdek 5090 and corrugated packings. • The COP and efficiency were found as 2.15 and 85.57 %, respectively. • Packing using grey water releases more contaminants than when using salt water. • Greater packing thickness enhances humidification performance and reduces pollution. • Increased wettability improves overall humidification efficiency. The current study centers on the design and fabrication of a direct-type evaporative cooling unit utilizing gray and salt water as working fluids. Three distinct packing configurations—Celdek 7090, Celdek 5090, and corrugated—were incorporated into a counterflow humidifier system to evaluate their performance in both humidification and water filtration. The air Reynolds number varied from 32,596 to 58,674, with performance metrics assessed across different packing configurations, wettabilities, and fluids. The system achieved an evaporation rate of 0.1158 g/s, a coefficient of performance (COP) of 2.15, a humidification efficiency of 85.57 %, and a cooling effect of 251.35 W, with Celdek 7090 outperforming the other configurations when paired with salt water. As packing thickness increased for gray water, CO 2 levels decreased by 5.83 %, 6.19 %, and 6.55 % for the Corrugated, Celdek 5090, and Celdek 7090 packings, respectively. Formaldehyde (HCHO) concentrations were reduced by 38.09 %, 40 %, and 38.88 %, while total volatile organic compounds (TVOC) decreased by 21.73 %, 23.80 %, and 26.31 %. Pollution levels were found to rise with increasing Reynolds number, yet tests confirmed that the air leaving the system was of superior quality. Enhanced packing thickness not only improved humidification performance but also further reduced pollution levels.

Energy and Built Environment
Manipal Academy of Higher Education (IN), Dr. NTR University of Health Sciences (IN)
Openalex Percentile: Top 36%
Adsorption and Cooling Systems
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.