Carbon-based pedicle screw fixation for lumbar fusion for degenerative pathologies in a cancer patient requiring radiotherapy

Spinal instability due to degenerative pathologies in patients with metastatic cancer presents significant challenges when spinal fusion and post-operative imaging and radiotherapy are required. Traditional metallic hardware hinders imaging quality and radiotherapy precision due to metal artefact. Carbon-fiber-reinforced polymer (CFRP) implants offer a novel solution, combining mechanical stability with radiolucency to enhance post-operative multidisciplinary care. We present the case of a patient with metastatic cancer requiring spinal stabilization and fusion. To address the dual needs of spinal stabilization and radiotherapy planning, CFRP pedicle screws and rods were used. Postoperative imaging and radiotherapy planning benefited from the radiolucent properties of the implants, enabling precise tumor targeting and disease monitoring. This case highlights the advantages of CFRP implants in managing cancer-associated spinal instability. The radiolucent nature of these implants allows for high-quality imaging and optimal radiotherapy delivery, addressing limitations associated with metallic implants.

Authors

Institutions

Publication Details

Journal
Journal of Surgical Case Reports
Published
2025-02-01
DOI
https://doi.org/10.1093/jscr/rjaf065
Primary Topic
Management of metastatic bone disease
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Carbon-based pedicle screw fixation for lumbar fusion for degenerative pathologies in a cancer patient requiring radiotherapy

Daniel Liu, Ralph J. Mobbs
Journal of Surgical Case Reports
Management of metastatic bone disease
article

Carbon-based pedicle screw fixation for lumbar fusion for degenerative pathologies in a cancer patient requiring radiotherapy

Daniel Liu, Ralph J. Mobbs
article en

Abstract

Spinal instability due to degenerative pathologies in patients with metastatic cancer presents significant challenges when spinal fusion and post-operative imaging and radiotherapy are required. Traditional metallic hardware hinders imaging quality and radiotherapy precision due to metal artefact. Carbon-fiber-reinforced polymer (CFRP) implants offer a novel solution, combining mechanical stability with radiolucency to enhance post-operative multidisciplinary care. We present the case of a patient with metastatic cancer requiring spinal stabilization and fusion. To address the dual needs of spinal stabilization and radiotherapy planning, CFRP pedicle screws and rods were used. Postoperative imaging and radiotherapy planning benefited from the radiolucent properties of the implants, enabling precise tumor targeting and disease monitoring. This case highlights the advantages of CFRP implants in managing cancer-associated spinal instability. The radiolucent nature of these implants allows for high-quality imaging and optimal radiotherapy delivery, addressing limitations associated with metallic implants.

Journal of Surgical Case ReportsVol. 2025(2)
UNSW Sydney (AU), Prince of Wales Hospital (AU)
Openalex Percentile: Top 94%
Management of metastatic bone disease
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Carbon-based pedicle screw fixation for lumbar fusion for degenerative pathologies in a cancer patient requiring radiotherapy — Daniel Liu, Ralph J. Mobbs · Journal of Surgical Case Reports (2025) | TGRS Research Map | TGRS