Chat-GPT Powered IoT devices using regularizing the data for an efficient management systems

Abstract Fetal Electrocardiogram (FECG) signals represent vital instruments for examining any irregularities in the heart’s functioning. Contemporary wearable technologies, including smartwatches and smartphones, now come with sophisticated sensors and computational systems designed to gather and process FECG signals from users. Lately, large language models such as T5 have attracted interest due to their capabilities in handling intricate patterns within data, positioning them as promising options for classifying morphological FECG signals and detecting arrhythmias. Nevertheless, diagnosing FECG signals on devices with limited resources presents considerable challenges owing to the complicated nature of the signals and the computational demands of implementing such algorithms on wearable tools. To tackle these difficulties, this paper suggests a strategy that merges T5-based learning methodologies to attain two main goals: (i) reducing the complexity of learning models without sacrificing diagnostic precision and (ii) ensuring performance in resource-limited wearable devices for ongoing monitoring of FECG signals. The research further investigates the implementation of the suggested T5-based algorithm through Software Codesign techniques to improve resource efficiency, concentrating on factors like reduced latency, decreased hardware usage, and enhanced energy efficiency. Comprehensive experiments were conducted using diverse FECG datasets and validated. The proposed T5-based methodology demonstrated significant improvements in diagnosing FECG signals compared to other learning frameworks, showcasing its effectiveness in managing complex data patterns and achieving high diagnostic performance. While the experimental findings highlight the T5-based model's potential for use in wearable devices. the study focused on the algorithm's adaptability and performance in software environments, paving the way for future exploration into resource-efficient implementations suitable for wearable applications.

Authors

Institutions

Publication Details

Journal
Journal of Smart Internet of Things
Published
2024-12-01
DOI
https://doi.org/10.2478/jsiot-2024-0020
Citations
1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Chat-GPT Powered IoT devices using regularizing the data for an efficient management systems

Shilpa Patil, T. Anne Ramya
1 citations
Journal of Smart Internet of Things
ECG Monitoring and Analysis
0.40
article

Chat-GPT Powered IoT devices using regularizing the data for an efficient management systems

Shilpa Patil, T. Anne Ramya
article en
1 citations

Abstract

Abstract Fetal Electrocardiogram (FECG) signals represent vital instruments for examining any irregularities in the heart’s functioning. Contemporary wearable technologies, including smartwatches and smartphones, now come with sophisticated sensors and computational systems designed to gather and process FECG signals from users. Lately, large language models such as T5 have attracted interest due to their capabilities in handling intricate patterns within data, positioning them as promising options for classifying morphological FECG signals and detecting arrhythmias. Nevertheless, diagnosing FECG signals on devices with limited resources presents considerable challenges owing to the complicated nature of the signals and the computational demands of implementing such algorithms on wearable tools. To tackle these difficulties, this paper suggests a strategy that merges T5-based learning methodologies to attain two main goals: (i) reducing the complexity of learning models without sacrificing diagnostic precision and (ii) ensuring performance in resource-limited wearable devices for ongoing monitoring of FECG signals. The research further investigates the implementation of the suggested T5-based algorithm through Software Codesign techniques to improve resource efficiency, concentrating on factors like reduced latency, decreased hardware usage, and enhanced energy efficiency. Comprehensive experiments were conducted using diverse FECG datasets and validated. The proposed T5-based methodology demonstrated significant improvements in diagnosing FECG signals compared to other learning frameworks, showcasing its effectiveness in managing complex data patterns and achieving high diagnostic performance. While the experimental findings highlight the T5-based model's potential for use in wearable devices. the study focused on the algorithm's adaptability and performance in software environments, paving the way for future exploration into resource-efficient implementations suitable for wearable applications.

Journal of Smart Internet of ThingsVol. 2024(2)
St. Peter's Institute of Higher Education and Research (IN)
Openalex Percentile: Top 29%
ECG Monitoring and Analysis
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.