Aqueous flow in the anterior chamber with angle-supported intraocular lens

Inserting of anterior chamber phakic intraocular lenses are emerging as a transformative option for vision correction, offering individuals with high myopia and thin corneas a safe and effective solution without compromising the natural lens. Implantation of a Z-shaped anterior chamber lens fourth generation (ZSAL-4) can change the typical flow patterns of aqueous humor. To study this flow patterns, we utilized advanced computational fluid dynamics using Ansys Fluent. This method originated as a novel approach to measuring fluid flow and comprehending the complex mechanics of human eye. This research displays the effect of anterior chamber depth and White to White on velocity, pressure, wall shear stress, skin friction coefficient, strain rate, stream function, and pathlines.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-02-01
DOI
https://doi.org/10.1063/5.0254470
Citations
6
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
10.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aqueous flow in the anterior chamber with angle-supported intraocular lens

A. Benerji Babu, Ajay Kumar, M. R. Flarence
6 citations
Physics of Fluids
Intraocular Surgery and Lenses
10.24
article

Aqueous flow in the anterior chamber with angle-supported intraocular lens

A. Benerji Babu, Ajay Kumar, M. R. Flarence
article en
6 citations

Abstract

Inserting of anterior chamber phakic intraocular lenses are emerging as a transformative option for vision correction, offering individuals with high myopia and thin corneas a safe and effective solution without compromising the natural lens. Implantation of a Z-shaped anterior chamber lens fourth generation (ZSAL-4) can change the typical flow patterns of aqueous humor. To study this flow patterns, we utilized advanced computational fluid dynamics using Ansys Fluent. This method originated as a novel approach to measuring fluid flow and comprehending the complex mechanics of human eye. This research displays the effect of anterior chamber depth and White to White on velocity, pressure, wall shear stress, skin friction coefficient, strain rate, stream function, and pathlines.

Physics of FluidsVol. 37(2)
National Institute of Technology Warangal (IN), Kakatiya University (IN)
Openalex Percentile: Top 2%
Intraocular Surgery and Lenses
10.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Aqueous flow in the anterior chamber with angle-supported intraocular lens — A. Benerji Babu, Ajay Kumar, et al. · Physics of Fluids (2025) | TGRS Research Map | TGRS