Fast Determination of Oxygen in FeSiAl magnetic alloy by Inert Gas Fusion Method

Abstract A fast method that combines inert gas fusion with infrared absorption spectrometry for determination of total oxygen in FeSiAl magnetic alloy has been established. The whole analyzing process was introduced, especially the selection of sample weight, analytical power, fluxes and calibration. The blank test, precision test and spiked recovery test were conducted to verify the suitability and accuracy of the proposed method. Limit of quantifications were in the range of 0.010% to 0.012%, while relative standard deviations were less 9.5%. The recovery rates of oxygen in potassium hydrogen phthalate were between 90% and 107%. The inert gas fusion-infrared method of testing a sample needs 4 min. It has shown that the new method is accurate and efficient.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-02-01
DOI
https://doi.org/10.1088/1742-6596/2959/1/012001
Primary Topic
Metallic Glasses and Amorphous Alloys
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast Determination of Oxygen in FeSiAl magnetic alloy by Inert Gas Fusion Method

Xinyao Zhang, Yongqiang Zhang, Qianqian Chen, Pan Liu et al.
Journal of Physics Conference Series
Metallic Glasses and Amorphous Alloys
article

Fast Determination of Oxygen in FeSiAl magnetic alloy by Inert Gas Fusion Method

Xinyao Zhang, Yongqiang Zhang, Qianqian Chen, Pan Liu, Shuo Wang, Jianhao Zhang, Lijuan Zhang
article en

Abstract

Abstract A fast method that combines inert gas fusion with infrared absorption spectrometry for determination of total oxygen in FeSiAl magnetic alloy has been established. The whole analyzing process was introduced, especially the selection of sample weight, analytical power, fluxes and calibration. The blank test, precision test and spiked recovery test were conducted to verify the suitability and accuracy of the proposed method. Limit of quantifications were in the range of 0.010% to 0.012%, while relative standard deviations were less 9.5%. The recovery rates of oxygen in potassium hydrogen phthalate were between 90% and 107%. The inert gas fusion-infrared method of testing a sample needs 4 min. It has shown that the new method is accurate and efficient.

Journal of Physics Conference SeriesVol. 2959(1)
Luoyang Cement Engineering Design and Research Institute (CN), China State Shipbuilding (China) (CN), Xiamen Tobacco Industry (China) (CN), Luoyang Institute of Science and Technology (CN)
Openalex Percentile: Top 97%
Metallic Glasses and Amorphous Alloys
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fast Determination of Oxygen in FeSiAl magnetic alloy by Inert Gas Fusion Method — Xinyao Zhang, Yongqiang Zhang, et al. · Journal of Physics Conference Series (2025) | TGRS Research Map | TGRS