A New Coumarin‐Based Fluorescent Chemosensor for Selection Detection of Zinc Ions in Aqueous Ethanol

In this study, a coumarin-based Schiff base (1) was designed and synthesized as a Zn<sup>2+</sup>-selective fluorescent chemosensor based on the PET mechanism. The structure of compound 1 was characterized by <sup>1</sup>H NMR and <sup>13</sup>C NMR. The fluorescence properties of this chemosensor toward various metal ions were explored by fluorescence and UV-vis spectra. The results indicated that the chemosensor had high selectivity toward Zn<sup>2+</sup> over other coexisting metal ions. The binding stoichiometry of 1 toward Zn<sup>2+</sup> was determined to be 1:1 by Job's plot. Furthermore, the chemosensor was reversible for Zn<sup>2+</sup> in an ethanol/H<sub>2</sub>O (7:3, V/V) solution by the addition of Na<sub>2</sub> EDTA. The above experimental results demonstrate that 1 can be used as a fluorescent chemosensor for the real-time detection of Zn<sup>2+</sup> in biological species and environmental systems.

Authors

Institutions

Publication Details

Journal
Luminescence
Published
2025-02-01
DOI
https://doi.org/10.1002/bio.70122
Citations
2
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
1.51
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A New Coumarin‐Based Fluorescent Chemosensor for Selection Detection of Zinc Ions in Aqueous Ethanol

Long Yan, Yajun Ma, Wensheng Yang, Wan Yang
2 citations
Luminescence
Molecular Sensors and Ion Detection
1.51
article

A New Coumarin‐Based Fluorescent Chemosensor for Selection Detection of Zinc Ions in Aqueous Ethanol

Long Yan, Yajun Ma, Wensheng Yang, Wan Yang
article en
2 citations

Abstract

In this study, a coumarin-based Schiff base (1) was designed and synthesized as a Zn<sup>2+</sup>-selective fluorescent chemosensor based on the PET mechanism. The structure of compound 1 was characterized by <sup>1</sup>H NMR and <sup>13</sup>C NMR. The fluorescence properties of this chemosensor toward various metal ions were explored by fluorescence and UV-vis spectra. The results indicated that the chemosensor had high selectivity toward Zn<sup>2+</sup> over other coexisting metal ions. The binding stoichiometry of 1 toward Zn<sup>2+</sup> was determined to be 1:1 by Job's plot. Furthermore, the chemosensor was reversible for Zn<sup>2+</sup> in an ethanol/H<sub>2</sub>O (7:3, V/V) solution by the addition of Na<sub>2</sub> EDTA. The above experimental results demonstrate that 1 can be used as a fluorescent chemosensor for the real-time detection of Zn<sup>2+</sup> in biological species and environmental systems.

LuminescenceVol. 40(2)
Yulin University (CN)
Openalex Percentile: Top 21%
Molecular Sensors and Ion Detection
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.