Stability analysis of grid-forming converters under hybrid synchronous control mode

This study examines the dynamic responses of grid-forming converters operating under a hybrid synchronous control strategy, which integrates a power-frequency loop with phase-locked loop like technology. This control strategy aims to enhance the converter's responsiveness to current thresholds, thereby minimizing or shortening periods of synchronization losses. In this paper, a mathematical model is developed, and an analytical investigation is conducted to analyze the dynamic behavior of these converters under the influence of the hybrid synchronous control strategy, particularly after abrupt grid condition changes. The findings indicate that the hybrid synchronous control may prompt erroneous control actions under certain grid conditions and current thresholds. These erroneous actions can occur due to the specific characteristics of the system. As a result, the converter may become trapped in a state of current saturation. These theoretical predictions have been verified through controller hardware-in-the-loop experiments.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-02-01
DOI
https://doi.org/10.1049/icp.2024.3770
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability analysis of grid-forming converters under hybrid synchronous control mode

Philipp Hackl, Robert Schuerhuber, Ziqian Zhang
IET conference proceedings.
Power Systems and Renewable Energy
article

Stability analysis of grid-forming converters under hybrid synchronous control mode

Philipp Hackl, Robert Schuerhuber, Ziqian Zhang
article en

Abstract

This study examines the dynamic responses of grid-forming converters operating under a hybrid synchronous control strategy, which integrates a power-frequency loop with phase-locked loop like technology. This control strategy aims to enhance the converter's responsiveness to current thresholds, thereby minimizing or shortening periods of synchronization losses. In this paper, a mathematical model is developed, and an analytical investigation is conducted to analyze the dynamic behavior of these converters under the influence of the hybrid synchronous control strategy, particularly after abrupt grid condition changes. The findings indicate that the hybrid synchronous control may prompt erroneous control actions under certain grid conditions and current thresholds. These erroneous actions can occur due to the specific characteristics of the system. As a result, the converter may become trapped in a state of current saturation. These theoretical predictions have been verified through controller hardware-in-the-loop experiments.

IET conference proceedings.Vol. 2024(16)
Graz University of Technology (AT)
Affordable and clean energy
Openalex Percentile: Top 98%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.