As renewable energy sources increasingly integrate into the grid, ensuring compliance with power quality standards, particularly regarding harmonic distortion, becomes critical for both users and system operators. This study examines the impact of underground cable modelling on the prediction of harmonic distortion at the point of connection during harmonic assessments. Lumped, distributed, and cascade models were evaluated in both single-phase and three-phase cable configurations, with an emphasis on their influence on resonances observed in harmonic impedance. Cable length was considered as a parameter to quantify the impact of these models. Simulations conducted using DigSILENT PowerFactory® reveal that the distributed parameter model best predicts the first resonance as cable length increases. For cables longer than 6 km, significant discrepancies in harmonic impedance behaviour are observed between models. Moreover, models that include detailed cable construction features demonstrate increased damping of resonances. While model validation is outside the scope of this work, the findings underscore the importance of selecting the appropriate cable model for accurate harmonic analysis in power systems.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-02-01
DOI
https://doi.org/10.1049/icp.2024.3907
Primary Topic
Mechanical and Thermal Properties Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modelling aspects on cables in the frequency domain

Arturo Romero, Manuel De La Hoz, Dominique Alonso Sørensen
IET conference proceedings.
Mechanical and Thermal Properties Analysis
article

Modelling aspects on cables in the frequency domain

Arturo Romero, Manuel De La Hoz, Dominique Alonso Sørensen
article en

Abstract

As renewable energy sources increasingly integrate into the grid, ensuring compliance with power quality standards, particularly regarding harmonic distortion, becomes critical for both users and system operators. This study examines the impact of underground cable modelling on the prediction of harmonic distortion at the point of connection during harmonic assessments. Lumped, distributed, and cascade models were evaluated in both single-phase and three-phase cable configurations, with an emphasis on their influence on resonances observed in harmonic impedance. Cable length was considered as a parameter to quantify the impact of these models. Simulations conducted using DigSILENT PowerFactory® reveal that the distributed parameter model best predicts the first resonance as cable length increases. For cables longer than 6 km, significant discrepancies in harmonic impedance behaviour are observed between models. Moreover, models that include detailed cable construction features demonstrate increased damping of resonances. While model validation is outside the scope of this work, the findings underscore the importance of selecting the appropriate cable model for accurate harmonic analysis in power systems.

IET conference proceedings.Vol. 2024(16)
University of the Basque Country (ES)
Openalex Percentile: Top 97%
Mechanical and Thermal Properties Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.