Design and Optimization of THz Refractive Index Diamond Shaped Hollow Core Biosensor for Brain Tissue Detection and Behaviour Prediction

The diagnosis of brain tumors remains a challenging and resource-intensive task due to the complexity of brain tissue and the limitations of existing diagnostic tools. Biosensors operating in THz regime can be used to monitor changes in the characteristics of brain tissues, including refractive index, However, the technical drawbacks of such systems are high costs, long signal acquisition tim,e and the need for high-performance calculations. In this research, we proposed a Terahertz (THz) refractive index-based novel diamond hollow-core biosensor for examining various brain tissues. The biosensor has a sensitivity range of 1.30 to 1.40 RI and a figure of merit that falls between 51000 nm RIU −1 , allowing for precise and accurate real-time diagnosis. The second contribution involves applying advanced optimization approach to optimize the model parameters. With a sensitivity of 99.45%, specificity of 99.78%, precision of 99.51%, and total accuracy of 99.93% in identifying malignant brain tissues, performance analysis shows exceptional results.

Authors

Publication Details

Journal
ECS Journal of Solid State Science and Technology
Published
2025-02-24
DOI
https://doi.org/10.1149/2162-8777/adb991
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Optimization of THz Refractive Index Diamond Shaped Hollow Core Biosensor for Brain Tissue Detection and Behaviour Prediction

Azath Mubarakali, M. S., Hashim Elshafie, N. Vithyalakshmi
ECS Journal of Solid State Science and Technology
Photonic and Optical Devices
article

Design and Optimization of THz Refractive Index Diamond Shaped Hollow Core Biosensor for Brain Tissue Detection and Behaviour Prediction

Azath Mubarakali, M. S., Hashim Elshafie, N. Vithyalakshmi
article en

Abstract

The diagnosis of brain tumors remains a challenging and resource-intensive task due to the complexity of brain tissue and the limitations of existing diagnostic tools. Biosensors operating in THz regime can be used to monitor changes in the characteristics of brain tissues, including refractive index, However, the technical drawbacks of such systems are high costs, long signal acquisition tim,e and the need for high-performance calculations. In this research, we proposed a Terahertz (THz) refractive index-based novel diamond hollow-core biosensor for examining various brain tissues. The biosensor has a sensitivity range of 1.30 to 1.40 RI and a figure of merit that falls between 51000 nm RIU −1 , allowing for precise and accurate real-time diagnosis. The second contribution involves applying advanced optimization approach to optimize the model parameters. With a sensitivity of 99.45%, specificity of 99.78%, precision of 99.51%, and total accuracy of 99.93% in identifying malignant brain tissues, performance analysis shows exceptional results.

ECS Journal of Solid State Science and TechnologyVol. 14(3)
Openalex Percentile: Top 97%
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Optimization of THz Refractive Index Diamond Shaped Hollow Core Biosensor for Brain Tissue Detection and Behaviour Prediction — Azath Mubarakali, M. S., et al. · ECS Journal of Solid State Science and Technology (2025) | TGRS Research Map | TGRS