Study of Different Types of Ventilation and Cooling Systems of Bulb Hydrogenerators in a Three-Dimensional Setting

<div>The <b>Object</b> of research in the article is the ventilation and cooling system of bulb hydrogenerators. The <b>Subject</b> of study in the article is the design and efficiency of using the cooling system of various structural types for bulb hydro units. The <b>Purpose</b> of the work is to carry out a three-dimensional study of two cooling systems (axial and radial) of the bulb hydro unit of the Kanivskaya HPP with a rated 22 MW. Research <b>Tasks</b> include analysis of the main design solutions for effective cooling of bulb-type hydrogenerators, in particular, the use of radial, axial, and mixed cooling systems; formulation of the main assumptions for the three-dimensional ventilation and thermal calculation of the bulb hydrogenerator; carrying out a three-dimensional calculation for a hydrogenerator with axial ventilation; determining airflow speeds in the channels and temperatures of active parts of the hydrogenerator under the conditions of using discharge fans and without them; carrying out a three-dimensional calculation for a hydrogenerator with radial ventilation; determining airflow speeds in the channels and temperatures of the active parts of the hydrogenerator. <b>As a result of the study</b>, the main constructive solutions of cooling systems of bulb hydrogenerators were considered. On the basis of scientific developments, two main ventilation systems were formed and their functioning was considered on the example of the hydro unit of the Kanivska HPP. Using a three-dimensional study, a comparison of the efficiency of axial and radial ventilation systems was carried out. It was found that the forced axial system with two fans is the most optimal and reliable for removing heat from heat-generating elements, ensuring long-term operation and the necessary speeds in the cooling channels. This research makes a significant contribution to improving the efficiency of the cooling systems of bulb hydrogenerators, which is critical for their reliable and trouble-free operation.</div>

Authors

Institutions

Publication Details

Journal
SAE International Journal of Materials and Manufacturing
Published
2025-02-20
DOI
https://doi.org/10.4271/05-18-03-0020
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Different Types of Ventilation and Cooling Systems of Bulb Hydrogenerators in a Three-Dimensional Setting

Mariia Arefieva, Stanislav Kravchenko, Anton Zhukov, Oleksii Tretiak et al.
SAE International Journal of Materials and Manufacturing
Heat Transfer and Boiling Studies
article

Study of Different Types of Ventilation and Cooling Systems of Bulb Hydrogenerators in a Three-Dimensional Setting

Mariia Arefieva, Stanislav Kravchenko, Anton Zhukov, Oleksii Tretiak, Anton Kovryga, I.V. Shulga, Nataliia Penkovska, Pavlo Makarov, Serhii Serhiienko
article en

Abstract

<div>The <b>Object</b> of research in the article is the ventilation and cooling system of bulb hydrogenerators. The <b>Subject</b> of study in the article is the design and efficiency of using the cooling system of various structural types for bulb hydro units. The <b>Purpose</b> of the work is to carry out a three-dimensional study of two cooling systems (axial and radial) of the bulb hydro unit of the Kanivskaya HPP with a rated 22 MW. Research <b>Tasks</b> include analysis of the main design solutions for effective cooling of bulb-type hydrogenerators, in particular, the use of radial, axial, and mixed cooling systems; formulation of the main assumptions for the three-dimensional ventilation and thermal calculation of the bulb hydrogenerator; carrying out a three-dimensional calculation for a hydrogenerator with axial ventilation; determining airflow speeds in the channels and temperatures of active parts of the hydrogenerator under the conditions of using discharge fans and without them; carrying out a three-dimensional calculation for a hydrogenerator with radial ventilation; determining airflow speeds in the channels and temperatures of the active parts of the hydrogenerator. <b>As a result of the study</b>, the main constructive solutions of cooling systems of bulb hydrogenerators were considered. On the basis of scientific developments, two main ventilation systems were formed and their functioning was considered on the example of the hydro unit of the Kanivska HPP. Using a three-dimensional study, a comparison of the efficiency of axial and radial ventilation systems was carried out. It was found that the forced axial system with two fans is the most optimal and reliable for removing heat from heat-generating elements, ensuring long-term operation and the necessary speeds in the cooling channels. This research makes a significant contribution to improving the efficiency of the cooling systems of bulb hydrogenerators, which is critical for their reliable and trouble-free operation.</div>

SAE International Journal of Materials and ManufacturingVol. 18(3)
National Aerospace University – Kharkiv Aviation Institute (UA)
Openalex Percentile: Top 97%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies