A Study on Measures to achieve Net Zero and RE100 goals in Urban Water Cycle System

Urban water cycle systems(UWCS), including water treatment facilities, distribution facilities, sewers, and wastewater treatment facilities, are energy intensive and significant source of greenhouse gas (GHG) emissions, making the reduction of GHG emissions and the transition to eco-friendly energy essential. This study identifies specific GHG emission sources at each stage of the UWCS and proposes detailed methods to achieve a 40% reduction in GHG emissions, implement RE100, and attain Net Zero by employing insets and offsets. This study develops scenarios for insets and offsets based on the baseline process of the UWCS, and investigates potential pathways to reduce GHG emissions by quantifying emissions from each process. Internal insets, which are self-implemented and technical measures, are prioritized, while external offsets are applied to compensate for the remaining emissions. Internal insets include the application of anaerobic digesters and combined heat and power(CHP), improvements in energy efficiency of equipment, reduction in water pipe leakage, implementation of water footprint labeling, and installation of on-site photovoltaic system. External offsets comprise renewable energy certificates(REC), power purchase agreements(PPA), green hydrogen fuel for vehicles, natural sequestration improvement, and emission trading system. GHG emissions at each stage within the UWCS are quantified using modeling software. Based on these results, the effectiveness of insets and offsets in achieving a 40% GHG emissions reduction, Net Zero, and RE100 goal is analyzed. The baseline total GHG emissions for the UWCS are estimated at 4,732.8 tCO2eq/yr, of which 56.8% is identified as targets for internal insets, and the remaining 43.2% is reduced through external offsets. A 40% GHG reduction can be achieved through internal insets, and Net Zero can be attained by incorporating additionally applying external offsets. The total power demand of UWCS facilities and equipment is calculated as 572.8 kW. Renewable energy is generated through anaerobic digesters and CHP(116.1kW) as well as on-site PV(395.0 kW), while RE100 compliance is achieved by securing an aditional 61.7 kW through REC/PPA. Achieving Net Zero and RE100 requires prioritizing strategies for insets, offsets and efficient resource allocation. For this, the technical feasibility and self-implementation potential of reduction efforts and the external conditions for offsets, should be carefully reviewed to optimize implementation strategies. GHG reduction and renewable energy utilization in the UWCS are key priorities for addressing the climate crisis and achieving sustainable water resource management, requiring technological innovation and institutional support. The comprehensive and systematic application of GHG insets and offsets is the optimal approach to achieving these goals. Furthermore, modeling software serves as a key tool for quantifying GHG emissions and formulating concrete, viable GHG reduction strategies. In addition to the technical and institutional approaches proposed in this study, achieving Net Zero and implementing RE100 requires the integrated consideration of economic factors in the future.

Authors

Publication Details

Journal
Journal of Korean Society of Environmental Engineers
Published
2025-02-24
DOI
https://doi.org/10.4491/ksee.2025.47.2.128
Primary Topic
Energy and Environmental Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study on Measures to achieve Net Zero and RE100 goals in Urban Water Cycle System

Seyoung Ahn, Haerim Kim
Journal of Korean Society of Environmental Engineers
Energy and Environmental Systems
article

A Study on Measures to achieve Net Zero and RE100 goals in Urban Water Cycle System

Seyoung Ahn, Haerim Kim
article en

Abstract

Urban water cycle systems(UWCS), including water treatment facilities, distribution facilities, sewers, and wastewater treatment facilities, are energy intensive and significant source of greenhouse gas (GHG) emissions, making the reduction of GHG emissions and the transition to eco-friendly energy essential. This study identifies specific GHG emission sources at each stage of the UWCS and proposes detailed methods to achieve a 40% reduction in GHG emissions, implement RE100, and attain Net Zero by employing insets and offsets. This study develops scenarios for insets and offsets based on the baseline process of the UWCS, and investigates potential pathways to reduce GHG emissions by quantifying emissions from each process. Internal insets, which are self-implemented and technical measures, are prioritized, while external offsets are applied to compensate for the remaining emissions. Internal insets include the application of anaerobic digesters and combined heat and power(CHP), improvements in energy efficiency of equipment, reduction in water pipe leakage, implementation of water footprint labeling, and installation of on-site photovoltaic system. External offsets comprise renewable energy certificates(REC), power purchase agreements(PPA), green hydrogen fuel for vehicles, natural sequestration improvement, and emission trading system. GHG emissions at each stage within the UWCS are quantified using modeling software. Based on these results, the effectiveness of insets and offsets in achieving a 40% GHG emissions reduction, Net Zero, and RE100 goal is analyzed. The baseline total GHG emissions for the UWCS are estimated at 4,732.8 tCO2eq/yr, of which 56.8% is identified as targets for internal insets, and the remaining 43.2% is reduced through external offsets. A 40% GHG reduction can be achieved through internal insets, and Net Zero can be attained by incorporating additionally applying external offsets. The total power demand of UWCS facilities and equipment is calculated as 572.8 kW. Renewable energy is generated through anaerobic digesters and CHP(116.1kW) as well as on-site PV(395.0 kW), while RE100 compliance is achieved by securing an aditional 61.7 kW through REC/PPA. Achieving Net Zero and RE100 requires prioritizing strategies for insets, offsets and efficient resource allocation. For this, the technical feasibility and self-implementation potential of reduction efforts and the external conditions for offsets, should be carefully reviewed to optimize implementation strategies. GHG reduction and renewable energy utilization in the UWCS are key priorities for addressing the climate crisis and achieving sustainable water resource management, requiring technological innovation and institutional support. The comprehensive and systematic application of GHG insets and offsets is the optimal approach to achieving these goals. Furthermore, modeling software serves as a key tool for quantifying GHG emissions and formulating concrete, viable GHG reduction strategies. In addition to the technical and institutional approaches proposed in this study, achieving Net Zero and implementing RE100 requires the integrated consideration of economic factors in the future.

Journal of Korean Society of Environmental EngineersVol. 47(2)
Openalex Percentile: Top 97%
Energy and Environmental Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.