Screen printed graphite electrode modified with two-dimen-sional leaf-like zeolitic imidazolate framework-L (Zn) for efficient electrochemical sensing of sulphite

In this paper, we describe the use of a screen-printed graphite electrode modified with a two-dimensional leaf-like zeolitic imidazolate framework-L (Zn), ZIF-L (Zn) for the deter¬mination of sulphite. We started by using linear sweep voltammetry to investigate the redox properties of the modified electrode at different scan rates (10 to 400 mV s-1). Next, we evaluated sulphite oxidation in the modified electrode. Using differential pulse voltammetry (DPV), the linear dynamic range of 0.04-900.0 µM and the limit of detection (3s/m) of 0.01 μM were obtained. DPV was also used to quantify sulphite in various real samples using the standard addition method.

Authors

Institutions

Publication Details

Journal
Journal of Electrochemical Science and Engineering
Published
2025-02-23
DOI
https://doi.org/10.5599/jese.2580
Citations
14
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
8.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Screen printed graphite electrode modified with two-dimen-sional leaf-like zeolitic imidazolate framework-L (Zn) for efficient electrochemical sensing of sulphite

Ban Waheed Hussein Bdair, Mustafa Mudhafar, Qais R. Lahhob, Satar Jabbar Rahi Algraittee et al.
14 citations
Journal of Electrochemical Science and Engineering
Conducting polymers and applications
8.49
article

Screen printed graphite electrode modified with two-dimen-sional leaf-like zeolitic imidazolate framework-L (Zn) for efficient electrochemical sensing of sulphite

Ban Waheed Hussein Bdair, Mustafa Mudhafar, Qais R. Lahhob, Satar Jabbar Rahi Algraittee, Raed Muslim Muhibes, Firas Abdul Abass Sukir
article en
14 citations

Abstract

In this paper, we describe the use of a screen-printed graphite electrode modified with a two-dimensional leaf-like zeolitic imidazolate framework-L (Zn), ZIF-L (Zn) for the deter¬mination of sulphite. We started by using linear sweep voltammetry to investigate the redox properties of the modified electrode at different scan rates (10 to 400 mV s-1). Next, we evaluated sulphite oxidation in the modified electrode. Using differential pulse voltammetry (DPV), the linear dynamic range of 0.04-900.0 µM and the limit of detection (3s/m) of 0.01 μM were obtained. DPV was also used to quantify sulphite in various real samples using the standard addition method.

Journal of Electrochemical Science and Engineering
University of Technology - Iraq (IQ), Thi Qar University (IQ), University of Misan (IQ), University of Kerbala (IQ)
Openalex Percentile: Top 2%
Conducting polymers and applications
8.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.