Ultrasensitive Water Contaminant Detection with Transcription Factor Interfaced Microcantilevers

Water contamination by harmful chemicals is a growing global concern, creating a need to develop technologies that can detect a range of target compounds at the required concentrations. Here, we address this need by merging biological allosteric transcription factors with DNA-coated nanomechanical microcantilevers to detect chemicals in water with a digital readout. After proof-of-concept demonstration and optimization to detect anhydrotetracycline with the TetR transcription factor, we use the CadC transcription factor to detect Pb<sup>2+</sup> and Cd<sup>2+</sup> in water at concentrations down to 2 and 1 ppb, respectively, in less than 15 min. A computational model suggests this improvement in sensitivity could be achieved by the DNA-coated microcantilever surface changing the transcription factor binding properties. Our findings demonstrate a promising approach for water quality monitoring with fast, highly sensitive, digital readout.

Authors

Institutions

Publication Details

Journal
ACS Nano
Published
2025-02-24
DOI
https://doi.org/10.1021/acsnano.4c17598
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasensitive Water Contaminant Detection with Transcription Factor Interfaced Microcantilevers

Jean‐François Gaillard, Gajendra S. Shekhawat, Julius B. Lucks, Vinayak P. Dravid et al.
2 citations
ACS Nano
Analytical Chemistry and Sensors
1.47
article

Ultrasensitive Water Contaminant Detection with Transcription Factor Interfaced Microcantilevers

Jean‐François Gaillard, Gajendra S. Shekhawat, Julius B. Lucks, Vinayak P. Dravid, Jaeyoung K. Jung, Tyler Lucci, A. Samuel, Dilip Agarwal
article en
2 citations

Abstract

Water contamination by harmful chemicals is a growing global concern, creating a need to develop technologies that can detect a range of target compounds at the required concentrations. Here, we address this need by merging biological allosteric transcription factors with DNA-coated nanomechanical microcantilevers to detect chemicals in water with a digital readout. After proof-of-concept demonstration and optimization to detect anhydrotetracycline with the TetR transcription factor, we use the CadC transcription factor to detect Pb<sup>2+</sup> and Cd<sup>2+</sup> in water at concentrations down to 2 and 1 ppb, respectively, in less than 15 min. A computational model suggests this improvement in sensitivity could be achieved by the DNA-coated microcantilever surface changing the transcription factor binding properties. Our findings demonstrate a promising approach for water quality monitoring with fast, highly sensitive, digital readout.

ACS NanoVol. 19(9)
Northwestern University (US), Université Bourgogne Franche-Comté (FR)
Clean water and sanitation
Openalex Percentile: Top 22%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ultrasensitive Water Contaminant Detection with Transcription Factor Interfaced Microcantilevers — Jean‐François Gaillard, Gajendra S. Shekhawat, et al. · ACS Nano (2025) | TGRS Research Map | TGRS