In Vitro Investigation of Microcatheter Behavior During Microsphere Injection in Transarterial Radioembolization

Our study demonstrated that microsphere distribution during transarterial radioembolization (TARE) is affected by catheter motion. Furthermore, increased catheter motion was observed as a result of the injection profile. Predictive tools such as the contrast CBCT and scout dose use different injection profiles compared to therapeutic TARE injections, potentially altering catheter tip behaviour and microsphere distribution, which could compromise their predictive values. Additionally, current TARE microsphere injection guidelines provide limited details, which may lead to variability across institutes and interventional radiologists. Standardizing injection techniques could reduce catheter motion variability and may facilitate more consistent and predictable microsphere distribution patterns.

Authors

Institutions

Publication Details

Journal
Journal of Endovascular Therapy
Published
2025-02-24
DOI
https://doi.org/10.1177/15266028251318953
Citations
4
Primary Topic
Hepatocellular Carcinoma Treatment and Prognosis
Type
article
Field-Weighted Citation Impact
5.29

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vitro Investigation of Microcatheter Behavior During Microsphere Injection in Transarterial Radioembolization

Hadi Mirgolbabaee, Joey Roosen, Erik Groot Jebbink, J. Frank W. Nijsen et al.
4 citations
Journal of Endovascular Therapy
Hepatocellular Carcinoma Treatment and Prognosis
5.29
article

In Vitro Investigation of Microcatheter Behavior During Microsphere Injection in Transarterial Radioembolization

Hadi Mirgolbabaee, Joey Roosen, Erik Groot Jebbink, J. Frank W. Nijsen, Tristan G. Vlogman, Tess J. Snoeijink, Jan L. van der Hoek
article en
4 citations

Abstract

Our study demonstrated that microsphere distribution during transarterial radioembolization (TARE) is affected by catheter motion. Furthermore, increased catheter motion was observed as a result of the injection profile. Predictive tools such as the contrast CBCT and scout dose use different injection profiles compared to therapeutic TARE injections, potentially altering catheter tip behaviour and microsphere distribution, which could compromise their predictive values. Additionally, current TARE microsphere injection guidelines provide limited details, which may lead to variability across institutes and interventional radiologists. Standardizing injection techniques could reduce catheter motion variability and may facilitate more consistent and predictable microsphere distribution patterns.

Journal of Endovascular Therapy
Radboud University Nijmegen (NL), Radboud University Medical Center (NL), University of Twente (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Openalex Percentile: Top 5%
Hepatocellular Carcinoma Treatment and Prognosis
5.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In Vitro Investigation of Microcatheter Behavior During Microsphere Injection in Transarterial Radioembolization — Hadi Mirgolbabaee, Joey Roosen, et al. · Journal of Endovascular Therapy (2025) | TGRS Research Map | TGRS