A Compact Orthosis Compliance Monitoring Device Using Pressure Sensors and Accelerometers: Design and Proof-of-Concept Testing

Monitoring orthosis compliance using patient diaries is subjective, as patients can overestimate their levels of device use. An objective way to monitor compliance is required because if an orthotic prescription is not followed, the orthosis will not work as intended. This study aimed to develop and validate a device that monitors orthosis compliance objectively using pressure and acceleration. Fifteen participants were recruited to test the device's ability to estimate wear time during the performance of several grip patterns and whilst completing selected activities of daily living. Sensor threshold values were used to discern whether users were wearing their orthosis or not. No differences between pressure sensor and accelerometer-based wear time estimations were found. The device's pressure-based wear time estimations were found to have a specificity of 92.7 ± 16.4% and sensitivity of 74.0 ± 41.3%, whilst accelerometer-based wear time estimates had a specificity of 66.1 ± 34.7% and sensitivity of 86.2 ± 8.0%. This study successfully demonstrated the feasibility of monitoring hand orthosis compliance using pressure or acceleration. This device has the potential to provide insight into the effectiveness of both existing and novel orthotics, benefitting both clinical practice and research.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-02-22
DOI
https://doi.org/10.3390/s25051352
Citations
2
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Compact Orthosis Compliance Monitoring Device Using Pressure Sensors and Accelerometers: Design and Proof-of-Concept Testing

Angela E. Kedgley, Matthew D. Gardiner, Devi Baruni Devanand
2 citations
Sensors
Muscle activation and electromyography studies
1.35
article

A Compact Orthosis Compliance Monitoring Device Using Pressure Sensors and Accelerometers: Design and Proof-of-Concept Testing

Angela E. Kedgley, Matthew D. Gardiner, Devi Baruni Devanand
article en
2 citations

Abstract

Monitoring orthosis compliance using patient diaries is subjective, as patients can overestimate their levels of device use. An objective way to monitor compliance is required because if an orthotic prescription is not followed, the orthosis will not work as intended. This study aimed to develop and validate a device that monitors orthosis compliance objectively using pressure and acceleration. Fifteen participants were recruited to test the device's ability to estimate wear time during the performance of several grip patterns and whilst completing selected activities of daily living. Sensor threshold values were used to discern whether users were wearing their orthosis or not. No differences between pressure sensor and accelerometer-based wear time estimations were found. The device's pressure-based wear time estimations were found to have a specificity of 92.7 ± 16.4% and sensitivity of 74.0 ± 41.3%, whilst accelerometer-based wear time estimates had a specificity of 66.1 ± 34.7% and sensitivity of 86.2 ± 8.0%. This study successfully demonstrated the feasibility of monitoring hand orthosis compliance using pressure or acceleration. This device has the potential to provide insight into the effectiveness of both existing and novel orthotics, benefitting both clinical practice and research.

SensorsVol. 25(5)
Wexham Park Hospital (GB), Nuffield Orthopaedic Centre (GB), Frimley Health NHS Foundation Trust (GB), University of Oxford (GB), Imperial College London (GB)
Wellcome, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 22%
Muscle activation and electromyography studies
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.