High-Performance ZIF-7@PANI Electrochemical Sensor for Simultaneous Trace Cadmium and Lead Detection in Water Samples: A Box–Behnken Design Optimization Approach

This study presents the development of an innovative electrochemical sensor for the simultaneous detection of cadmium (Cd<sup>2+</sup>) and lead (Pb<sup>2+</sup>) ions in environmental samples. The sensor is developed based on a composite material of zeolite imidazolate framework ZIF-7 and polyaniline (PANI), referred to as ZIF-7@PANI, where ZIF-7 is rapidly synthesized at room temperature and polyaniline used to enhance the conductivity of the composite. Characterization via X-ray diffraction (DRX), scanning electron microscopy (SEM), and Fourier transform infrared spectroscopy (FTIR) confirmed successful synthesis. The composite was applied to a glassy carbon electrode (GCE) using drop-casting for heavy metal ion detection. Experimental parameters-including pH, incubation time, deposited quantity, and drying time-were optimized using the Box-Behnken design. Under optimal conditions, the ZIF-7@PANI/GCE sensor demonstrated a broad dynamic concentration range (0.002-1 µM for Pb<sup>2+</sup> and 0.02-30 µM for Cd<sup>2+</sup>), with low detection limits (2.96 nM for Pb<sup>2+</sup> and 10.6 nM for Cd<sup>2+</sup>). It also exhibited strong anti-interference properties and high recovery rates (85-110%), highlighting its potential for real practical applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-02-22
DOI
https://doi.org/10.3390/s25051336
Citations
15
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
7.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Performance ZIF-7@PANI Electrochemical Sensor for Simultaneous Trace Cadmium and Lead Detection in Water Samples: A Box–Behnken Design Optimization Approach

Nadhem Missaoui, Nashwan Hussein Ali, Houcine Barhoumi, Hamza Kahri et al.
15 citations
Sensors
Electrochemical Analysis and Applications
7.73
article

High-Performance ZIF-7@PANI Electrochemical Sensor for Simultaneous Trace Cadmium and Lead Detection in Water Samples: A Box–Behnken Design Optimization Approach

Nadhem Missaoui, Nashwan Hussein Ali, Houcine Barhoumi, Hamza Kahri, Chama Mabrouk, Nicole J. Jaffrezic-Renault, Zouhaier Aloui, Carlos J. Martinez, Fraj Echouchene, Sondes Guesmi
article en
15 citations

Abstract

This study presents the development of an innovative electrochemical sensor for the simultaneous detection of cadmium (Cd<sup>2+</sup>) and lead (Pb<sup>2+</sup>) ions in environmental samples. The sensor is developed based on a composite material of zeolite imidazolate framework ZIF-7 and polyaniline (PANI), referred to as ZIF-7@PANI, where ZIF-7 is rapidly synthesized at room temperature and polyaniline used to enhance the conductivity of the composite. Characterization via X-ray diffraction (DRX), scanning electron microscopy (SEM), and Fourier transform infrared spectroscopy (FTIR) confirmed successful synthesis. The composite was applied to a glassy carbon electrode (GCE) using drop-casting for heavy metal ion detection. Experimental parameters-including pH, incubation time, deposited quantity, and drying time-were optimized using the Box-Behnken design. Under optimal conditions, the ZIF-7@PANI/GCE sensor demonstrated a broad dynamic concentration range (0.002-1 µM for Pb<sup>2+</sup> and 0.02-30 µM for Cd<sup>2+</sup>), with low detection limits (2.96 nM for Pb<sup>2+</sup> and 10.6 nM for Cd<sup>2+</sup>). It also exhibited strong anti-interference properties and high recovery rates (85-110%), highlighting its potential for real practical applications.

SensorsVol. 25(5)
Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), University of Monastir (TN), Université de Montpellier (FR), University of Samarra (IQ), Institut des Sciences Analytiques (FR), Institut Européen des Membranes (FR), King Khalid University (SA), University of Sousse (TN)
Clean water and sanitation
Openalex Percentile: Top 2%
Electrochemical Analysis and Applications
7.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.