Sampling and analysis of H2S and Hg from evaporative geothermal cooling towers: The Italian experience

• Collecting stable and representative samples of air emitted from cooling towers presents a complex challenge. • Here a thorough examination of standard methodologies was conducted to suit their applicability to geothermal plants. • These customized methods are currently adopted for monitoring H 2 S and Hg emissions. The Italian regulatory framework on geothermal power plants requires measurement of the emission of H 2 S and Hg from cooling towers. Sampling of emitted air in geothermal plants is a quite complex task requiring specific non-standard methods in order to collect stable and representative samples. A direct application of standard methods for H 2 S and Hg emissions to cooling tower is often not suitable or difficult to apply. The standard methods indeed were developed for sampling in the stacks of combustion plants such as power generation or cement production plants. The drastic difference in temperature, humidity, air flow composition and velocity and moreover geometrical difference between stacks with diameters of few meters compared to cells of cooling towers, very often over 5–9 m, required a special setup of methods for sampling and analysis. Enel Green Power and Consiglio Nazionale delle Ricerche (Italy) thus have carried out a screening of the existing methods and some of them were customized and extended for their application on cooling towers of geothermal power plants. The main results obtained provided suitable sampling and analysis methods for H 2 S in the range 0.2–25 mg/Nm 3 and for mercury between 20–500 µg/Nm 3 . The aforementioned sampling and analysis methods are currently adopted by EGP and by the regional agency for environmental protection (ARPAT) for the measurement of H 2 S and Hg emission from cooling towers of geothermal power plants in Italy.

Authors

Institutions

Publication Details

Journal
Geothermics
Published
2025-02-24
DOI
https://doi.org/10.1016/j.geothermics.2025.103291
Primary Topic
Odor and Emission Control Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sampling and analysis of H2S and Hg from evaporative geothermal cooling towers: The Italian experience

Marco Paci, Antonio Caprai, Alessandro D’Ulivo, Alessandro Lenzi et al.
Geothermics
Odor and Emission Control Technologies
article

Sampling and analysis of H2S and Hg from evaporative geothermal cooling towers: The Italian experience

Marco Paci, Antonio Caprai, Alessandro D’Ulivo, Alessandro Lenzi, Beatrice Campanella, Marco Carlo Mascherpa, Massimo Onor, Alessandro Bettini
article en

Abstract

• Collecting stable and representative samples of air emitted from cooling towers presents a complex challenge. • Here a thorough examination of standard methodologies was conducted to suit their applicability to geothermal plants. • These customized methods are currently adopted for monitoring H 2 S and Hg emissions. The Italian regulatory framework on geothermal power plants requires measurement of the emission of H 2 S and Hg from cooling towers. Sampling of emitted air in geothermal plants is a quite complex task requiring specific non-standard methods in order to collect stable and representative samples. A direct application of standard methods for H 2 S and Hg emissions to cooling tower is often not suitable or difficult to apply. The standard methods indeed were developed for sampling in the stacks of combustion plants such as power generation or cement production plants. The drastic difference in temperature, humidity, air flow composition and velocity and moreover geometrical difference between stacks with diameters of few meters compared to cells of cooling towers, very often over 5–9 m, required a special setup of methods for sampling and analysis. Enel Green Power and Consiglio Nazionale delle Ricerche (Italy) thus have carried out a screening of the existing methods and some of them were customized and extended for their application on cooling towers of geothermal power plants. The main results obtained provided suitable sampling and analysis methods for H 2 S in the range 0.2–25 mg/Nm 3 and for mercury between 20–500 µg/Nm 3 . The aforementioned sampling and analysis methods are currently adopted by EGP and by the regional agency for environmental protection (ARPAT) for the measurement of H 2 S and Hg emission from cooling towers of geothermal power plants in Italy.

GeothermicsVol. 129
Institute of Geosciences and Earth Resources (IT), Institute for the Chemistry of OrganoMetallic Compounds (IT), Enel (Italy) (IT)
Sustainable cities and communities
Openalex Percentile: Top 98%
Odor and Emission Control Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.