Coagulation Performance of Hydrolysed (Alum) and Pre-Hydrolysed (PAC) Coagulants for Ammoniacal Nitrogen (AN) Removal from Matured Leachate

Abstract Coagulation is commonly used in removing pollutants from matured leachate because of the low biodegradability of leachate that only suits the physical-chemical treatment method. Coagulant types are affecting the removal of pollutants as a consequence of leachate variability characteristics. This research aimed to assess the performance of hydrolysed alum (aluminium chloride) and pre-hydrolysed PAC (polyaluminium chloride) coagulants in AN removal from matured leachate under dosage, pH and settling time. It was found that the optimal conditions for hydrolysed alum were obtained at a dosage of 3000 mg/L, pH 4, settling time 30 minutes with 22% AN removal meanwhile for pre-hydrolysed PAC coagulants were obtained at a dosage of 2000 mg/L, pH 7, time of 20 minutes with 29% AN removal respectively. In conclusion, pre-hydrolysed PAC coagulants performed better in AN removal than hydrolysed alum coagulants.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Earth and Environmental Science
Published
2025-02-01
DOI
https://doi.org/10.1088/1755-1315/1453/1/012055
Citations
1
Primary Topic
Wastewater Treatment and Nitrogen Removal
Type
article
Field-Weighted Citation Impact
8.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coagulation Performance of Hydrolysed (Alum) and Pre-Hydrolysed (PAC) Coagulants for Ammoniacal Nitrogen (AN) Removal from Matured Leachate

Nur Shaylinda Mohd Zin, Laila Wahida Mohamad Zailani, Nur Ain Natasha Abdul Rasid, M.I.H.M Hazmee
1 citations
IOP Conference Series Earth and Environmental Science
Wastewater Treatment and Nitrogen Removal
8.82
article

Coagulation Performance of Hydrolysed (Alum) and Pre-Hydrolysed (PAC) Coagulants for Ammoniacal Nitrogen (AN) Removal from Matured Leachate

Nur Shaylinda Mohd Zin, Laila Wahida Mohamad Zailani, Nur Ain Natasha Abdul Rasid, M.I.H.M Hazmee
article en
1 citations

Abstract

Abstract Coagulation is commonly used in removing pollutants from matured leachate because of the low biodegradability of leachate that only suits the physical-chemical treatment method. Coagulant types are affecting the removal of pollutants as a consequence of leachate variability characteristics. This research aimed to assess the performance of hydrolysed alum (aluminium chloride) and pre-hydrolysed PAC (polyaluminium chloride) coagulants in AN removal from matured leachate under dosage, pH and settling time. It was found that the optimal conditions for hydrolysed alum were obtained at a dosage of 3000 mg/L, pH 4, settling time 30 minutes with 22% AN removal meanwhile for pre-hydrolysed PAC coagulants were obtained at a dosage of 2000 mg/L, pH 7, time of 20 minutes with 29% AN removal respectively. In conclusion, pre-hydrolysed PAC coagulants performed better in AN removal than hydrolysed alum coagulants.

IOP Conference Series Earth and Environmental ScienceVol. 1453(1)
Tun Hussein Onn University of Malaysia (MY)
Openalex Percentile: Top 6%
Wastewater Treatment and Nitrogen Removal
8.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.