Experimental Study on the Bearing Performance of Segmented Prestressed Assembled Foundation with Full-Scale Testing

This paper aims to address limitations of assembled foundations through a systematic approach involving the careful design and validation of precast foundations for transmission towers. Specifically, we introduce a novel method known as the Segmented Prestressed Assembled Foundation (SPAF), and demonstrate its application through a detailed design process based on an actual engineering project. Subsequent to the design phase, finite element models of both the proposed SPAF and conventional foundations are developed to facilitate a comprehensive comparison of their respective load-bearing performances. Furthermore, we conduct a full-scale test of the SPAF to verify the safety and efficacy of the newly proposed foundation design scheme. The results of our study indicate that the SPAF exhibits sufficient load-bearing performance comparable to that of a conventional cast-in-place foundation. Moreover, the inter-component connection method employed enhances the integrity of the SPAF, ensuring adequate joint strength and safety. Additionally, the SPAF offers significant advantages in terms of structural design and construction methods.

Authors

Institutions

Publication Details

Journal
Journal of Advanced Concrete Technology
Published
2025-02-24
DOI
https://doi.org/10.3151/jact.23.123
Citations
2
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
2.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on the Bearing Performance of Segmented Prestressed Assembled Foundation with Full-Scale Testing

Xiangrui Meng, Jie Zou, Juncai Liu, Juan Liu et al.
2 citations
Journal of Advanced Concrete Technology
Structural Behavior of Reinforced Concrete
2.01
article

Experimental Study on the Bearing Performance of Segmented Prestressed Assembled Foundation with Full-Scale Testing

Xiangrui Meng, Jie Zou, Juncai Liu, Juan Liu, Ge Zhao, Li Tian, Guodong Shao, Taotao Zheng
article en
2 citations

Abstract

This paper aims to address limitations of assembled foundations through a systematic approach involving the careful design and validation of precast foundations for transmission towers. Specifically, we introduce a novel method known as the Segmented Prestressed Assembled Foundation (SPAF), and demonstrate its application through a detailed design process based on an actual engineering project. Subsequent to the design phase, finite element models of both the proposed SPAF and conventional foundations are developed to facilitate a comprehensive comparison of their respective load-bearing performances. Furthermore, we conduct a full-scale test of the SPAF to verify the safety and efficacy of the newly proposed foundation design scheme. The results of our study indicate that the SPAF exhibits sufficient load-bearing performance comparable to that of a conventional cast-in-place foundation. Moreover, the inter-component connection method employed enhances the integrity of the SPAF, ensuring adequate joint strength and safety. Additionally, the SPAF offers significant advantages in terms of structural design and construction methods.

Journal of Advanced Concrete TechnologyVol. 23(2)
Shandong University (CN), PowerChina (China) (CN)
Natural Science Foundation of Shandong Province
Openalex Percentile: Top 16%
Structural Behavior of Reinforced Concrete
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.