Combining the WRF model and LCZ scheme to assess spatiotemporal variations of thermal comfort in Shenzhen's built-up areas

• Incorporating LCZ map into WRF substantially enhances wind speed simulation accuracy. • Southwest Shenzhen has the worst thermal comfort due to high temperatures and low winds. • Higher development intensity of built-up LCZ correlates with poorer thermal comfort. • Intra-LCZ thermal comfort varies significantly with spatiotemporal conditions. Applying the local climate zone (LCZ) scheme is effective for guiding the urban morphology to enhance outdoor thermal comfort. Previous studies have extensively explored thermal comfort in built-up areas and their inter-LCZ variations by applying temperature attributes. However, the combined effects of other factors (humidity and wind speed) have received little attention, and intra-LCZ thermal comfort variations are not fully understood. This study aimed to assess spatiotemporal variations in thermal comfort across built-up LCZs based on multiple meteorological factors. We incorporated the Weather Research and Forecasting model with the LCZ scheme and calculated the net effective temperature using simulated air temperature, relative humidity, and wind speed. Inter-LCZ and intra-LCZ thermal comfort variations were analyzed using spatial autocorrelation and statistical methods. The study was conducted during both dry and wet seasons in the subtropical city of Shenzhen, China. The results revealed that 1) the southwestern area experienced the poorest thermal comfort during the wet season owing to high temperatures and low wind speeds; 2) significant inter-LCZ thermal comfort differences existed within the same season, with higher development intensity correlating to poorer thermal comfort; and 3) intra-LCZ thermal comfort varied across spatial locations and fluctuated with the season and time of day.

Authors

Institutions

Publication Details

Journal
Sustainable Cities and Society
Published
2025-02-24
DOI
https://doi.org/10.1016/j.scs.2025.106252
Citations
8
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
6.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combining the WRF model and LCZ scheme to assess spatiotemporal variations of thermal comfort in Shenzhen's built-up areas

Zhengdong Huang, Jiacheng Huang, Wenyu Liu
8 citations
Sustainable Cities and Society
Urban Heat Island Mitigation
6.39
article

Combining the WRF model and LCZ scheme to assess spatiotemporal variations of thermal comfort in Shenzhen's built-up areas

Zhengdong Huang, Jiacheng Huang, Wenyu Liu
article en
8 citations

Abstract

• Incorporating LCZ map into WRF substantially enhances wind speed simulation accuracy. • Southwest Shenzhen has the worst thermal comfort due to high temperatures and low winds. • Higher development intensity of built-up LCZ correlates with poorer thermal comfort. • Intra-LCZ thermal comfort varies significantly with spatiotemporal conditions. Applying the local climate zone (LCZ) scheme is effective for guiding the urban morphology to enhance outdoor thermal comfort. Previous studies have extensively explored thermal comfort in built-up areas and their inter-LCZ variations by applying temperature attributes. However, the combined effects of other factors (humidity and wind speed) have received little attention, and intra-LCZ thermal comfort variations are not fully understood. This study aimed to assess spatiotemporal variations in thermal comfort across built-up LCZs based on multiple meteorological factors. We incorporated the Weather Research and Forecasting model with the LCZ scheme and calculated the net effective temperature using simulated air temperature, relative humidity, and wind speed. Inter-LCZ and intra-LCZ thermal comfort variations were analyzed using spatial autocorrelation and statistical methods. The study was conducted during both dry and wet seasons in the subtropical city of Shenzhen, China. The results revealed that 1) the southwestern area experienced the poorest thermal comfort during the wet season owing to high temperatures and low wind speeds; 2) significant inter-LCZ thermal comfort differences existed within the same season, with higher development intensity correlating to poorer thermal comfort; and 3) intra-LCZ thermal comfort varied across spatial locations and fluctuated with the season and time of day.

Sustainable Cities and SocietyVol. 122
Shenzhen University (CN), Guangdong-Hongkong-Macau Joint Laboratory of Collaborative Innovation for Environmental Quality (CN)
China Postdoctoral Science Foundation
Openalex Percentile: Top 4%
Urban Heat Island Mitigation
6.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.