Development of flexible nanoporous gold electrodes for the detection of glucose

The development of implantable glucose sensors is of significant interest in the management of diabetes. This work focuses on developing an implantable, biocompatible nanoporous gold electrode prototype based on Kapton® for the subcutaneous detection of glucose. The electrodes were first modified with a layer containing glucose oxidase and Os(2,2'-bipyridine)<sub>2</sub>Cl·PVI (Os(bpy)<sub>2</sub>Cl PVI). An additional polymeric layer containing poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate) was then added to reduce biofouling and foreign body reaction effects. The modified electrode had a V<sub>MAX</sub> of 211 ± 13 μA cm<sup>-2</sup> and a K<sub>Mapp</sub> of 6.1 ± 0.8 mM in pseudo physiological conditions, with a linear detection range from 1 to 4 mM and a sensitivity of 28.6 ± 2.1 μA cm<sup>-2</sup> mM<sup>-1</sup>. In artificial plasma, the response of the sensor was saturated at 3 mM, with a V<sub>MAX</sub> of 113 ± 10 μA cm<sup>-2</sup> and a K<sub>Mapp</sub> of 2.1 ± 0.4 mM with a linear detection range from 1 to 2.5 mM and a sensitivity of 14.6 ± 3.3 μA cm<sup>-2</sup> mM<sup>-1</sup>. Mechanical stress testing demonstrated that there was a 40 % reduction of the redox polymer coverage after 320 deformation events, however the catalytic activity was still detectable after 160 events. Minimal cytotoxicity effects of the electrodes were observed. When subcutaneously implanted the electrodes showed fairly good mechanical stability after one week and detachment of the metallic layer on some electrodes after 21 days, probably due to electrode bending. A limited foreign body reaction was observed. These results indicated that the electrodes could be implanted for a period of up to 1 week.

Authors

Institutions

Publication Details

Journal
Bioelectrochemistry
Published
2025-02-24
DOI
https://doi.org/10.1016/j.bioelechem.2025.108949
Citations
7
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
5.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of flexible nanoporous gold electrodes for the detection of glucose

Kavita Jayakumar, Edmond Magner, Tanushree Mandal, Wolfgang W. Schuhmann et al.
7 citations
Bioelectrochemistry
Electrochemical sensors and biosensors
5.11
article

Development of flexible nanoporous gold electrodes for the detection of glucose

Kavita Jayakumar, Edmond Magner, Tanushree Mandal, Wolfgang W. Schuhmann, Nicolas Mano, Andrés Felipe Quintero-Jaime, Claudine Boiziau, Julia Álvarez-Malmagro, Dónal Leech, Anna Lielpētere, Denise Demurtas, Arvind Rathore, Serguei Belochapkine
article en
7 citations

Abstract

The development of implantable glucose sensors is of significant interest in the management of diabetes. This work focuses on developing an implantable, biocompatible nanoporous gold electrode prototype based on Kapton® for the subcutaneous detection of glucose. The electrodes were first modified with a layer containing glucose oxidase and Os(2,2'-bipyridine)<sub>2</sub>Cl·PVI (Os(bpy)<sub>2</sub>Cl PVI). An additional polymeric layer containing poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate) was then added to reduce biofouling and foreign body reaction effects. The modified electrode had a V<sub>MAX</sub> of 211 ± 13 μA cm<sup>-2</sup> and a K<sub>Mapp</sub> of 6.1 ± 0.8 mM in pseudo physiological conditions, with a linear detection range from 1 to 4 mM and a sensitivity of 28.6 ± 2.1 μA cm<sup>-2</sup> mM<sup>-1</sup>. In artificial plasma, the response of the sensor was saturated at 3 mM, with a V<sub>MAX</sub> of 113 ± 10 μA cm<sup>-2</sup> and a K<sub>Mapp</sub> of 2.1 ± 0.4 mM with a linear detection range from 1 to 2.5 mM and a sensitivity of 14.6 ± 3.3 μA cm<sup>-2</sup> mM<sup>-1</sup>. Mechanical stress testing demonstrated that there was a 40 % reduction of the redox polymer coverage after 320 deformation events, however the catalytic activity was still detectable after 160 events. Minimal cytotoxicity effects of the electrodes were observed. When subcutaneously implanted the electrodes showed fairly good mechanical stability after one week and detachment of the metallic layer on some electrodes after 21 days, probably due to electrode bending. A limited foreign body reaction was observed. These results indicated that the electrodes could be implanted for a period of up to 1 week.

BioelectrochemistryVol. 165
Centre National de la Recherche Scientifique (FR), Université de Bordeaux (FR), Inserm (FR), Ollscoil na Gaillimhe – University of Galway (IE), University of Limerick (IE), Bordeaux Population Health (FR), Centre de recherche Paul Pascal (FR), Ruhr University Bochum (DE)
European Commission, Université de Bordeaux, Horizon 2020 Framework Programme
Openalex Percentile: Top 5%
Electrochemical sensors and biosensors
5.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.