Automatic skin flash optimization in breast and chestwall VMAT with static angle modulated ports: Effect of HU and flash margin size on plan quality and robustness

Skin flash is typically added to breast and chestwall plans to ensure robust target coverage in the presence of respiratory motion, anatomic changes, and small setup uncertainties. Adding skin flash in volumetric modulated arc therapy (VMAT) plans is an iterative and manual process. RapidArc dynamic (RAD) is a new solution that integrates a dynamic collimator and static-gantry angle modulated ports directly into arc delivery. The automatic skin flash tool (ASF) allows users to automatically add skin flash directly within the optimizer. The user must select the thickness and Hounsfield Units (HUs) of the flash region, but the optimal values are not currently known. For 13 left- and right-sided breast and chestwall patients, RAD plans were created with no skin flash and with ASF with thickness of 5 to 20 mm and HU of -500 to 0 HU. To assess plan quality, DVH metrics for planning target volume (PTV), heart, ipsilateral lung, contralateral lung, and contralateral breast were recorded. To assess plan robustness, the isocenter was shifted 5 mm, moving the target 5 mm anteriorly into the flash region. The changes in clinical target volume (CTV) D95% and D99% were recorded. A paired t-test was used to determine if changes in plan quality or robustness were statistically significant (p ≤ 0.05). The addition of ≥ 7 mm of skin flash resulted in robust plans. Varying the HU did not affect robustness. Increasing the skin flash beyond 10 mm increased PTV V105%. This increase was much larger in the 0 HU plans than in the -350 HU plans. We therefore recommend using -350 HU and 7-10 mm of skin flash for anticipated inter- and intra-fraction motion of 5 mm.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2025-02-21
DOI
https://doi.org/10.1002/acm2.70036
Citations
4
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
7.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic skin flash optimization in breast and chestwall VMAT with static angle modulated ports: Effect of HU and flash margin size on plan quality and robustness

Emily Hubley, Boon‐Keng Teo, Brandon Koger, Taoran Li et al.
4 citations
Journal of Applied Clinical Medical Physics
Advanced Radiotherapy Techniques
7.53
article

Automatic skin flash optimization in breast and chestwall VMAT with static angle modulated ports: Effect of HU and flash margin size on plan quality and robustness

Emily Hubley, Boon‐Keng Teo, Brandon Koger, Taoran Li, Ryan Scheuermann, Michael Salerno, Lei Dong
article en
4 citations

Abstract

Skin flash is typically added to breast and chestwall plans to ensure robust target coverage in the presence of respiratory motion, anatomic changes, and small setup uncertainties. Adding skin flash in volumetric modulated arc therapy (VMAT) plans is an iterative and manual process. RapidArc dynamic (RAD) is a new solution that integrates a dynamic collimator and static-gantry angle modulated ports directly into arc delivery. The automatic skin flash tool (ASF) allows users to automatically add skin flash directly within the optimizer. The user must select the thickness and Hounsfield Units (HUs) of the flash region, but the optimal values are not currently known. For 13 left- and right-sided breast and chestwall patients, RAD plans were created with no skin flash and with ASF with thickness of 5 to 20 mm and HU of -500 to 0 HU. To assess plan quality, DVH metrics for planning target volume (PTV), heart, ipsilateral lung, contralateral lung, and contralateral breast were recorded. To assess plan robustness, the isocenter was shifted 5 mm, moving the target 5 mm anteriorly into the flash region. The changes in clinical target volume (CTV) D95% and D99% were recorded. A paired t-test was used to determine if changes in plan quality or robustness were statistically significant (p ≤ 0.05). The addition of ≥ 7 mm of skin flash resulted in robust plans. Varying the HU did not affect robustness. Increasing the skin flash beyond 10 mm increased PTV V105%. This increase was much larger in the 0 HU plans than in the -350 HU plans. We therefore recommend using -350 HU and 7-10 mm of skin flash for anticipated inter- and intra-fraction motion of 5 mm.

Journal of Applied Clinical Medical PhysicsVol. 26(5)
Varian Medical Systems (Germany) (DE), University of Pennsylvania (US)
Openalex Percentile: Top 3%
Advanced Radiotherapy Techniques
7.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.