Modeling and Performance Analysis on an Integrated System Combining Supercritical Carbon Dioxide Brayton Cycle With Leakage Feedback Utilizing a Heat Pump or Direct Compression

Abstract CO2 leakage due to the coexistence of pressure differentials and clearances within the integrated turbine-alternator-compressor (TAC) of the kW-level sCO2 Brayton cycle is a key issue affecting cycle efficiency and long-term stable operation. To analyze the impact of leakage and feedback, this study examined the integrated system of the sCO2 Brayton cycle with leakage feedback and compared the system performance differences between heat pump feedback and direct compression feedback. Thermodynamic models for the Brayton cycle and feedback unit were established, and the effects of varying key parameters were analyzed. A genetic algorithm was employed to further optimize the system. The selection suggestion charts for the feedback unit were obtained. It is recommended to choose a direct compression feedback unit for conditions with a cavity pressure higher than 6.41 MPa, whereas a heat pump feedback unit is recommended for other conditions. The heat pump feedback unit has advantages particularly at high rotational speeds, low leakage factors, and low cavity pressures. The efficiency of the optimized integrated system is improved by up to 12.53%. The net power accounted for only 53.6% of the turbine output power, the main cycle compression power accounted for 32.1%, the TAC losses accounted for 10.7%, and the total compression power of the feedback unit accounted for 3.7%. Ignoring the internal leakage and losses of TAC can overestimate the power generation capacity of the Brayton cycle, resulting in it being only 79% of the ideal case after considering losses and power consumption.

Authors

Institutions

Publication Details

Journal
Journal of Engineering for Gas Turbines and Power
Published
2025-02-22
DOI
https://doi.org/10.1115/1.4067989
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling and Performance Analysis on an Integrated System Combining Supercritical Carbon Dioxide Brayton Cycle With Leakage Feedback Utilizing a Heat Pump or Direct Compression

Yinke Qi, Peixue Jiang, Xiaofeng Ma, Yinhai Zhu
Journal of Engineering for Gas Turbines and Power
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Modeling and Performance Analysis on an Integrated System Combining Supercritical Carbon Dioxide Brayton Cycle With Leakage Feedback Utilizing a Heat Pump or Direct Compression

Yinke Qi, Peixue Jiang, Xiaofeng Ma, Yinhai Zhu
article en

Abstract

Abstract CO2 leakage due to the coexistence of pressure differentials and clearances within the integrated turbine-alternator-compressor (TAC) of the kW-level sCO2 Brayton cycle is a key issue affecting cycle efficiency and long-term stable operation. To analyze the impact of leakage and feedback, this study examined the integrated system of the sCO2 Brayton cycle with leakage feedback and compared the system performance differences between heat pump feedback and direct compression feedback. Thermodynamic models for the Brayton cycle and feedback unit were established, and the effects of varying key parameters were analyzed. A genetic algorithm was employed to further optimize the system. The selection suggestion charts for the feedback unit were obtained. It is recommended to choose a direct compression feedback unit for conditions with a cavity pressure higher than 6.41 MPa, whereas a heat pump feedback unit is recommended for other conditions. The heat pump feedback unit has advantages particularly at high rotational speeds, low leakage factors, and low cavity pressures. The efficiency of the optimized integrated system is improved by up to 12.53%. The net power accounted for only 53.6% of the turbine output power, the main cycle compression power accounted for 32.1%, the TAC losses accounted for 10.7%, and the total compression power of the feedback unit accounted for 3.7%. Ignoring the internal leakage and losses of TAC can overestimate the power generation capacity of the Brayton cycle, resulting in it being only 79% of the ideal case after considering losses and power consumption.

Journal of Engineering for Gas Turbines and PowerVol. 147(10)
Tsinghua University (CN)
Openalex Percentile: Top 97%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.