Practical application and calibration of apparent half-saturation coefficients for aerobic granular sludge modelling: Limitations and value

Aerobic granular sludge (AGS) models for process optimization and control require balancing model complexity and accuracy. This study explores the strengths and limitations of using 0D-biofilm models based on apparent-half saturation coefficients (K S,app ) and evaluates a recently proposed procedure, based on 1D-biofilm model outcomes ( 1D-biofilm-to-K S,app procedure), for calibrating K S,app usig routine monitoring data commonly available from full-scale facilities. Two case-studies were investigated, differing in reactor size and process conditions, both characterized by operation as sequencing batch reactors. The implications of using such estimates in 0D-biofilm AGS models were assessed, also considering the possibility of incorporating vertical gradients in the reactor model during the non-mixed anaerobic feeding phase. When implemented in a completely mixed batch reactor model, significant relative errors (30–82 %) were observed in predicting steady-state effluent concentrations (ammonium, phosphorous and biodegradable COD), with negligible improvements when vertical concentration gradients were included. Based upon sensitivity analysis outcomes, direct calibration of K S,app was carried out by fitting predicted vs. average measured effluent concentrations. The application of these new K S,app values under dynamic conditions proved that 0D-biofilm models calibrated using routine monitoring data may not reliably capture the typical variability of AGS processes (Theil's Inequality Coefficient > 0.36 for ammonium and phosphorous). • Apparent half-saturation coefficients were estimated for two AGS case studies. • Critical aspects in the procedure adopted for K S,app estimation were identified. • K S,app from the procedure adopted caused errors >30 % for steady state simulations. • Plug-flow hydraulics inclusion in 0D-biofilm models poorly improved model accuracy. • 0D-biofilm models based on K S,app were scarcely appropriate for dynamic simulation.

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2025-02-22
DOI
https://doi.org/10.1016/j.jwpe.2025.107292
Primary Topic
Wastewater Treatment and Nitrogen Removal
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Practical application and calibration of apparent half-saturation coefficients for aerobic granular sludge modelling: Limitations and value

Mauro Pesenti, Roberto Canziani, Giovanna Rizzardi, Luca Formaggia et al.
Journal of Water Process Engineering
Wastewater Treatment and Nitrogen Removal
article

Practical application and calibration of apparent half-saturation coefficients for aerobic granular sludge modelling: Limitations and value

Mauro Pesenti, Roberto Canziani, Giovanna Rizzardi, Luca Formaggia, Andrea Turolla, Arianna Catenacci, Elia Paini
article en

Abstract

Aerobic granular sludge (AGS) models for process optimization and control require balancing model complexity and accuracy. This study explores the strengths and limitations of using 0D-biofilm models based on apparent-half saturation coefficients (K S,app ) and evaluates a recently proposed procedure, based on 1D-biofilm model outcomes ( 1D-biofilm-to-K S,app procedure), for calibrating K S,app usig routine monitoring data commonly available from full-scale facilities. Two case-studies were investigated, differing in reactor size and process conditions, both characterized by operation as sequencing batch reactors. The implications of using such estimates in 0D-biofilm AGS models were assessed, also considering the possibility of incorporating vertical gradients in the reactor model during the non-mixed anaerobic feeding phase. When implemented in a completely mixed batch reactor model, significant relative errors (30–82 %) were observed in predicting steady-state effluent concentrations (ammonium, phosphorous and biodegradable COD), with negligible improvements when vertical concentration gradients were included. Based upon sensitivity analysis outcomes, direct calibration of K S,app was carried out by fitting predicted vs. average measured effluent concentrations. The application of these new K S,app values under dynamic conditions proved that 0D-biofilm models calibrated using routine monitoring data may not reliably capture the typical variability of AGS processes (Theil's Inequality Coefficient > 0.36 for ammonium and phosphorous). • Apparent half-saturation coefficients were estimated for two AGS case studies. • Critical aspects in the procedure adopted for K S,app estimation were identified. • K S,app from the procedure adopted caused errors >30 % for steady state simulations. • Plug-flow hydraulics inclusion in 0D-biofilm models poorly improved model accuracy. • 0D-biofilm models based on K S,app were scarcely appropriate for dynamic simulation.

Journal of Water Process EngineeringVol. 71
Politecnico di Milano (IT)
Politecnico di Milano
Openalex Percentile: Top 98%
Wastewater Treatment and Nitrogen Removal
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.