Uncertainty in cardiovascular digital twins despite non-normal errors in 4D flow MRI: Identifying reliable biomarkers such as ventricular relaxation rate

Cardiovascular digital twins and mechanistic models can be used to obtain new biomarkers from patient-specific hemodynamic data. However, such model-derived biomarkers are only clinically relevant if the uncertainty of the biomarkers is smaller than the variation between timepoints/patients. Unfortunately, this uncertainty is challenging to calculate, as the uncertainty of the underlying hemodynamic data is largely unknown and has several sources that are not additive or normally distributed. This violates normality assumptions of current methods; implying that also biomarkers have an unknown uncertainty. To remedy these problems, we herein present a method, with attached code, for uncertainty calculation of model-derived biomarkers using non-normal data. First, we estimated all sources of uncertainty, both normal and non-normal, in hemodynamic data used to personalize an existing model; the errors in 4D flow MRI-derived stroke volumes were 5-20 % and the blood pressure errors were 0 ± 8 mmHg. Second, we estimated the resulting model-derived biomarker uncertainty for 100 simulated datasets, sampled from the data distributions, by: 1) combining data uncertainties 2) parameter estimation, 3) profile-likelihood. The true biomarker values were found within a 95 % confidence interval in 98 % (median) of the cases. This shows both that our estimated data uncertainty is reasonable, and that we can use profile-likelihood despite the non-normality. Finally, we demonstrated that e.g. ventricular relaxation rate has a smaller uncertainty (∼10 %) than the variation across a clinical cohort (∼40 %), meaning that these biomarkers have clinical potential. Our results take us one step closer to the usage of model-derived biomarkers for cardiovascular patient characterization.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2025-02-22
DOI
https://doi.org/10.1016/j.compbiomed.2025.109878
Citations
7
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
9.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty in cardiovascular digital twins despite non-normal errors in 4D flow MRI: Identifying reliable biomarkers such as ventricular relaxation rate

Gunnar Cedersund, Kajsa Tunedal, Tino Ebbers
7 citations
Computers in Biology and Medicine
Advanced MRI Techniques and Applications
9.52
article

Uncertainty in cardiovascular digital twins despite non-normal errors in 4D flow MRI: Identifying reliable biomarkers such as ventricular relaxation rate

Gunnar Cedersund, Kajsa Tunedal, Tino Ebbers
article en
7 citations

Abstract

Cardiovascular digital twins and mechanistic models can be used to obtain new biomarkers from patient-specific hemodynamic data. However, such model-derived biomarkers are only clinically relevant if the uncertainty of the biomarkers is smaller than the variation between timepoints/patients. Unfortunately, this uncertainty is challenging to calculate, as the uncertainty of the underlying hemodynamic data is largely unknown and has several sources that are not additive or normally distributed. This violates normality assumptions of current methods; implying that also biomarkers have an unknown uncertainty. To remedy these problems, we herein present a method, with attached code, for uncertainty calculation of model-derived biomarkers using non-normal data. First, we estimated all sources of uncertainty, both normal and non-normal, in hemodynamic data used to personalize an existing model; the errors in 4D flow MRI-derived stroke volumes were 5-20 % and the blood pressure errors were 0 ± 8 mmHg. Second, we estimated the resulting model-derived biomarker uncertainty for 100 simulated datasets, sampled from the data distributions, by: 1) combining data uncertainties 2) parameter estimation, 3) profile-likelihood. The true biomarker values were found within a 95 % confidence interval in 98 % (median) of the cases. This shows both that our estimated data uncertainty is reasonable, and that we can use profile-likelihood despite the non-normality. Finally, we demonstrated that e.g. ventricular relaxation rate has a smaller uncertainty (∼10 %) than the variation across a clinical cohort (∼40 %), meaning that these biomarkers have clinical potential. Our results take us one step closer to the usage of model-derived biomarkers for cardiovascular patient characterization.

Computers in Biology and MedicineVol. 188
Linköping University (SE)
Knowledge Foundation, Stiftelsen Forska Utan Djurförsök, Region Östergötland, Hjärt-Lungfonden, Vetenskapsrådet, HORIZON EUROPE Framework Programme
Openalex Percentile: Top 2%
Advanced MRI Techniques and Applications
9.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.