Applicability of the OECD Test Guideline 201 to graphene-related materials: Dispersion stability matters

Graphene-related materials (GRMs) are used in many innovative applications for their outstanding physico-chemical properties. Their possible release could have critical consequences for the environment. According to a European Union regulation, one of the test guidelines (TG) that must be applied to check the environmental hazard of new substances is the OECD TG 201 - Algae and Cyanobacteria Growth Inhibition Test. It was developed for water-soluble substances, whereas GRMs are not: dispersed in aqueous media, they tend to aggregate and settle, changing their bioavailability. This work aims to evaluate the applicability of the TG 201 to GRMs by investigating the stability of GRMs dispersions (GDS) in the TG 201 medium, focusing on the stability criterion of TG 201, i.e. maintaining ± 20 % of the nominal initial concentration. Based on flow-cytometry, Turbiscan and Utermöhl sedimentation chamber measurements, the following factors were tested: (i) particle composition and (ii) concentration; (iii) application of turbulence; (iv) addition of dispersants; (v) presence/absence of the target organism. Strong agglomeration/aggregation and sedimentation phenomena were observed for all materials under all tested conditions, thus the stability criterion of TG 201 was not met. Nevertheless, this can be satisfied by allowing an adequate period of time (approx. 6 h) for the GRM dispersion to stabilize after its preparation. Only then, a detailed physico-chemical characterization of the suspended material is required, which must be reiterated at the end of the test.

Authors

Institutions

Publication Details

Journal
Ecotoxicology and Environmental Safety
Published
2025-02-22
DOI
https://doi.org/10.1016/j.ecoenv.2025.117888
Citations
1
Primary Topic
Graphene and Nanomaterials Applications
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Applicability of the OECD Test Guideline 201 to graphene-related materials: Dispersion stability matters

Viviana Jehová González, Emmanuel Flahaut, Fabio Candotto Carniel, G Caorsi et al.
1 citations
Ecotoxicology and Environmental Safety
Graphene and Nanomaterials Applications
0.67
article

Applicability of the OECD Test Guideline 201 to graphene-related materials: Dispersion stability matters

Viviana Jehová González, Emmanuel Flahaut, Fabio Candotto Carniel, G Caorsi, Ester Vázquez, Maurizio Prato, Morgan Légnani, Mauro Tretiach
article en
1 citations

Abstract

Graphene-related materials (GRMs) are used in many innovative applications for their outstanding physico-chemical properties. Their possible release could have critical consequences for the environment. According to a European Union regulation, one of the test guidelines (TG) that must be applied to check the environmental hazard of new substances is the OECD TG 201 - Algae and Cyanobacteria Growth Inhibition Test. It was developed for water-soluble substances, whereas GRMs are not: dispersed in aqueous media, they tend to aggregate and settle, changing their bioavailability. This work aims to evaluate the applicability of the TG 201 to GRMs by investigating the stability of GRMs dispersions (GDS) in the TG 201 medium, focusing on the stability criterion of TG 201, i.e. maintaining ± 20 % of the nominal initial concentration. Based on flow-cytometry, Turbiscan and Utermöhl sedimentation chamber measurements, the following factors were tested: (i) particle composition and (ii) concentration; (iii) application of turbulence; (iv) addition of dispersants; (v) presence/absence of the target organism. Strong agglomeration/aggregation and sedimentation phenomena were observed for all materials under all tested conditions, thus the stability criterion of TG 201 was not met. Nevertheless, this can be satisfied by allowing an adequate period of time (approx. 6 h) for the GRM dispersion to stabilize after its preparation. Only then, a detailed physico-chemical characterization of the suspended material is required, which must be reiterated at the end of the test.

Ecotoxicology and Environmental SafetyVol. 292
Université Toulouse III - Paul Sabatier (FR), University of Trieste (IT), University of Milan (IT), Centre Interuniversitaire de Recherche et d’Ingénierie des Matériaux (FR), Istituto Nazionale di Fisica Nucleare, Sezione di Milano (IT), University of Castilla-La Mancha (ES)
Openalex Percentile: Top 35%
Graphene and Nanomaterials Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.