Comparison Between Bispectral Index and Minimum Alveolar Concentration as Monitors for Depth of Anaesthesia and Recovery Profile Using Desflurane for General Anaesthesia

Introduction: To enhance recovery, we can use short acting agents and monitor depth of anaesthesia. Desflurane is less soluble in blood and has good emergence characteristics. Traditionally, MAC was used to assess the depth of anaesthesia and to aid in recovery from anaesthesia. Recently, Bispectral index (BIS) monitor has gained popularity for monitoring the depth of anaesthesia. The present study aims to compare the efficacy of BIS and corrected MAC as monitors for the depth of anaesthesia and the recovery profile of patients undergoing surgery under general anaesthesia Patients and Methods A prospective randomised comparative double blinded study was conducted. Sixty patients in the age group of 18–65 years were scheduled for mastectomy surgery under general anaesthesia with ASA grade 1 and 2 were included in the study and were randomly divided into two groups. Group B: Desflurane concentration was adjusted to maintain a BIS value of 45–55. Group M: Desflurane concentration was adjusted to maintain a target age-corrected MAC of 0.8–1.3 Results: Patients monitored with BIS had faster awakening and less consumption of desflurane. Conclusion: With the use of BIS monitor, there is less anaesthetic gas consumption and early recovery from anaesthesia, which makes it a superior choice for monitoring the depth of anaesthesia.

Authors

Institutions

Publication Details

Journal
Apollo Medicine
Published
2025-02-22
DOI
https://doi.org/10.1177/09760016251317277
Primary Topic
Anesthesia and Sedative Agents
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison Between Bispectral Index and Minimum Alveolar Concentration as Monitors for Depth of Anaesthesia and Recovery Profile Using Desflurane for General Anaesthesia

Gaganpreet Kaur, Preeti Adlakha, Arvinpreet Kour, Jasmeet Kaur et al.
Apollo Medicine
Anesthesia and Sedative Agents
article

Comparison Between Bispectral Index and Minimum Alveolar Concentration as Monitors for Depth of Anaesthesia and Recovery Profile Using Desflurane for General Anaesthesia

Gaganpreet Kaur, Preeti Adlakha, Arvinpreet Kour, Jasmeet Kaur, Akashdeep Singh
article en

Abstract

Introduction: To enhance recovery, we can use short acting agents and monitor depth of anaesthesia. Desflurane is less soluble in blood and has good emergence characteristics. Traditionally, MAC was used to assess the depth of anaesthesia and to aid in recovery from anaesthesia. Recently, Bispectral index (BIS) monitor has gained popularity for monitoring the depth of anaesthesia. The present study aims to compare the efficacy of BIS and corrected MAC as monitors for the depth of anaesthesia and the recovery profile of patients undergoing surgery under general anaesthesia Patients and Methods A prospective randomised comparative double blinded study was conducted. Sixty patients in the age group of 18–65 years were scheduled for mastectomy surgery under general anaesthesia with ASA grade 1 and 2 were included in the study and were randomly divided into two groups. Group B: Desflurane concentration was adjusted to maintain a BIS value of 45–55. Group M: Desflurane concentration was adjusted to maintain a target age-corrected MAC of 0.8–1.3 Results: Patients monitored with BIS had faster awakening and less consumption of desflurane. Conclusion: With the use of BIS monitor, there is less anaesthetic gas consumption and early recovery from anaesthesia, which makes it a superior choice for monitoring the depth of anaesthesia.

Apollo MedicineVol. 23(1_suppl)
Maharishi Markandeshwar University, Mullana (IN), Fortis Hospital (IN)
Openalex Percentile: Top 93%
Anesthesia and Sedative Agents
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines