Parameter Optimization, Morphological and Histological Characteristics of Accurate Bone Ablation by Femtosecond Laser: An In Vitro Study

The use of femtosecond laser for bone ablation has been demonstrated in numerous studies; however, the clinical application requires further optimization to meet safety, accuracy, and efficiency standards. This study aims to optimize the energy density parameter of a robot-controlled femtosecond laser surgical system for bone ablation by assessing temperature changes, ablation efficiency, and ablation effects. Furthermore, the morphological and histological characteristics of bone tissue were compared with those of conventional mechanical methods. The results indicated that a laser energy density of 1.05 J/cm<sup>2</sup> was optimal for bone ablation, maintaining the bone surface temperature below 47 °C and achieving an ablation efficiency of 0.145 mm<sup>3</sup>/s. The deviations in cavity diameters were significantly smaller for the laser group (6.58 ± 18.09 μm) compared to the bur group (80.09 ± 45.45 μm, <i>p</i> < 0.001, <i>N</i> = 5 per group). Femtosecond laser ablation produced cleaner cavity margins with minimal bone debris accumulation. Additionally, the adjacent Volkmann and Haversian canals retained their normal morphology, indicating limited mechanical and thermal damage to the bone tissue. The robot-controlled femtosecond laser system demonstrated the potential for achieving safe, accurate, efficient, and clean bone ablation, offering promising prospects for clinical applications.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-02-21
DOI
https://doi.org/10.3390/bioengineering12030217
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parameter Optimization, Morphological and Histological Characteristics of Accurate Bone Ablation by Femtosecond Laser: An In Vitro Study

Shanshan Liang, Yongsheng Zhou, Fusong Yuan, Hongqiang Ye et al.
Bioengineering
Laser Applications in Dentistry and Medicine
article

Parameter Optimization, Morphological and Histological Characteristics of Accurate Bone Ablation by Femtosecond Laser: An In Vitro Study

Shanshan Liang, Yongsheng Zhou, Fusong Yuan, Hongqiang Ye, Yiyang Wang
article en

Abstract

The use of femtosecond laser for bone ablation has been demonstrated in numerous studies; however, the clinical application requires further optimization to meet safety, accuracy, and efficiency standards. This study aims to optimize the energy density parameter of a robot-controlled femtosecond laser surgical system for bone ablation by assessing temperature changes, ablation efficiency, and ablation effects. Furthermore, the morphological and histological characteristics of bone tissue were compared with those of conventional mechanical methods. The results indicated that a laser energy density of 1.05 J/cm<sup>2</sup> was optimal for bone ablation, maintaining the bone surface temperature below 47 °C and achieving an ablation efficiency of 0.145 mm<sup>3</sup>/s. The deviations in cavity diameters were significantly smaller for the laser group (6.58 ± 18.09 μm) compared to the bur group (80.09 ± 45.45 μm, <i>p</i> < 0.001, <i>N</i> = 5 per group). Femtosecond laser ablation produced cleaner cavity margins with minimal bone debris accumulation. Additionally, the adjacent Volkmann and Haversian canals retained their normal morphology, indicating limited mechanical and thermal damage to the bone tissue. The robot-controlled femtosecond laser system demonstrated the potential for achieving safe, accurate, efficient, and clean bone ablation, offering promising prospects for clinical applications.

BioengineeringVol. 12(3)
Peking University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 95%
Laser Applications in Dentistry and Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Parameter Optimization, Morphological and Histological Characteristics of Accurate Bone Ablation by Femtosecond Laser: An In Vitro Study — Shanshan Liang, Yongsheng Zhou, et al. · Bioengineering (2025) | TGRS Research Map | TGRS