Synthesis of Polypyrrole‐Graphene Oxide (PPy/GO) from Deep Eutectic Solvent and Its Characterization for Determination of Metronidazole Pharmaceutical Substance Using Spectrofluorometric Technique

Abstract A polypyrrole‐graphene oxide (PPy/GO) nanocomposite was made chemically using a polymerization method in deep eutectic solvents made up of choline chloride and propionic acid in a 1:2 molar ratio. The purpose of this study is to examine the feasibility and efficacy of PPy/GO nanocomposite in the detection of metronidazole in pharmaceutical formulations utilizing spectrofluorometric techniques. Characterization of the synthesized PPy/GO nanocomposite was conducted using several methods such as transmission electron microscopy (TEM), scanning electron microscopy (SEM), Fourier‐transform infrared spectroscopy (FTIR), thermal gravimetric analysis (TGA), and X‐ray diffraction (XRD). The optimal parameters such as pH buffer solution, potential interferences, reaction duration, concentrations of metronidazole, and interference, and test in real sample were examined. Under the established ideal conditions, the curve of calibration exhibited a linear range of 0.3–20 µg/mL, with a correlation coefficient (R 2 ) of 0.98712. The limit of detection (LOD) was 0.09 µg/mL, while the limit of quantification (LOQ) was 0.29 µg/mL. The relative standard deviation (RSD) readings for five replicates of three metronidazole standard solutions (0.3, 10, or 20 µg/mL) were assessed, yielding RSD percentages ranging from 1.29% to 2.34% and error percentages from −3.33% to 1.20%, thereby demonstrating the method's precision and accuracy. This study provides a viable and useful way to detect metronidazole in pharmaceutical samples. Moreover, the data indicate that PPy/GO may constitute a novel category of fluorescence quenching reagent for medicinal applications. This approach is effective for regular analysis and quality control assays because of its relative freedom from interferences.

Authors

Institutions

Publication Details

Journal
ChemistrySelect
Published
2025-02-01
DOI
https://doi.org/10.1002/slct.202405486
Citations
8
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
5.84

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthesis of Polypyrrole‐Graphene Oxide (PPy/GO) from Deep Eutectic Solvent and Its Characterization for Determination of Metronidazole Pharmaceutical Substance Using Spectrofluorometric Technique

Haider M. Umran, Rebaz Anwar Omer, Aryan Fathulla Qader, Aseel A. Kareem et al.
8 citations
ChemistrySelect
Electrochemical sensors and biosensors
5.84
article

Synthesis of Polypyrrole‐Graphene Oxide (PPy/GO) from Deep Eutectic Solvent and Its Characterization for Determination of Metronidazole Pharmaceutical Substance Using Spectrofluorometric Technique

Haider M. Umran, Rebaz Anwar Omer, Aryan Fathulla Qader, Aseel A. Kareem, Hasan F. Alesary, Hani K. Ismail
article en
8 citations

Abstract

Abstract A polypyrrole‐graphene oxide (PPy/GO) nanocomposite was made chemically using a polymerization method in deep eutectic solvents made up of choline chloride and propionic acid in a 1:2 molar ratio. The purpose of this study is to examine the feasibility and efficacy of PPy/GO nanocomposite in the detection of metronidazole in pharmaceutical formulations utilizing spectrofluorometric techniques. Characterization of the synthesized PPy/GO nanocomposite was conducted using several methods such as transmission electron microscopy (TEM), scanning electron microscopy (SEM), Fourier‐transform infrared spectroscopy (FTIR), thermal gravimetric analysis (TGA), and X‐ray diffraction (XRD). The optimal parameters such as pH buffer solution, potential interferences, reaction duration, concentrations of metronidazole, and interference, and test in real sample were examined. Under the established ideal conditions, the curve of calibration exhibited a linear range of 0.3–20 µg/mL, with a correlation coefficient (R 2 ) of 0.98712. The limit of detection (LOD) was 0.09 µg/mL, while the limit of quantification (LOQ) was 0.29 µg/mL. The relative standard deviation (RSD) readings for five replicates of three metronidazole standard solutions (0.3, 10, or 20 µg/mL) were assessed, yielding RSD percentages ranging from 1.29% to 2.34% and error percentages from −3.33% to 1.20%, thereby demonstrating the method's precision and accuracy. This study provides a viable and useful way to detect metronidazole in pharmaceutical samples. Moreover, the data indicate that PPy/GO may constitute a novel category of fluorescence quenching reagent for medicinal applications. This approach is effective for regular analysis and quality control assays because of its relative freedom from interferences.

ChemistrySelectVol. 10(8)
University of Baghdad (IQ), University of Kerbala (IQ), Koya University (IQ)
Azarbaijan Shahid Madani University
Openalex Percentile: Top 4%
Electrochemical sensors and biosensors
5.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.