A Mode-Localized Micro-Electromechanical System Accelerometer with Force Rebalance Closed-Loop Control

This article proposes a force rebalance control scheme based on a mode-localized resonant accelerometer (ML-RXL), which is applied to address the limited measurement range problem of the ML-RXL. For the first time, an empirical response model of the weakly coupling resonators for the amplitude ratio output is established. Based on this, this paper builds an overall model of the force rebalance control system to analyze the sensitivity characteristics by simulations, which demonstrates that the scheme can effectively broaden the linear measurement range. It is demonstrated that the sensor exhibits a highly linear output within a measurement range of ±1 g, with a sensitivity of the feedback-control voltage output measured at 2.94 V/g. The measurement range is expanded by at least 6.7 times. Moreover, the results show that the minimum input-referred acceleration noise density of the sensor for the force rebalance control scheme is 3.29 μg/rtHz, and that the best bias instability is optimized to 5.34 μg with an integral time of 0.64 s.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-02-21
DOI
https://doi.org/10.3390/mi16030248
Citations
3
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
3.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Mode-Localized Micro-Electromechanical System Accelerometer with Force Rebalance Closed-Loop Control

Zhenxiang Qi, Xudong Zou, Kunfeng Wang, Zhaoyang Zhai et al.
3 citations
Micromachines
Mechanical and Optical Resonators
3.74
article

A Mode-Localized Micro-Electromechanical System Accelerometer with Force Rebalance Closed-Loop Control

Zhenxiang Qi, Xudong Zou, Kunfeng Wang, Zhaoyang Zhai, Bowen Wang, Zheng Wang
article en
3 citations

Abstract

This article proposes a force rebalance control scheme based on a mode-localized resonant accelerometer (ML-RXL), which is applied to address the limited measurement range problem of the ML-RXL. For the first time, an empirical response model of the weakly coupling resonators for the amplitude ratio output is established. Based on this, this paper builds an overall model of the force rebalance control system to analyze the sensitivity characteristics by simulations, which demonstrates that the scheme can effectively broaden the linear measurement range. It is demonstrated that the sensor exhibits a highly linear output within a measurement range of ±1 g, with a sensitivity of the feedback-control voltage output measured at 2.94 V/g. The measurement range is expanded by at least 6.7 times. Moreover, the results show that the minimum input-referred acceleration noise density of the sensor for the force rebalance control scheme is 3.29 μg/rtHz, and that the best bias instability is optimized to 5.34 μg with an integral time of 0.64 s.

MicromachinesVol. 16(3)
Chinese Academy of Sciences (CN), State Key Laboratory of Transducer Technology (CN), Aerospace Information Research Institute (CN), University of Chinese Academy of Sciences (CN)
Chinese Academy of Sciences, National Key Research and Development Program of China, Key Research Program of Frontier Science, Chinese Academy of Sciences
Affordable and clean energy
Openalex Percentile: Top 8%
Mechanical and Optical Resonators
3.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Mode-Localized Micro-Electromechanical System Accelerometer with Force Rebalance Closed-Loop Control — Zhenxiang Qi, Xudong Zou, et al. · Micromachines (2025) | TGRS Research Map | TGRS