Occupancy and Air Quality Model for Outdoor Events: A Strategy for Preventing Disease Transmission at Mass Events

This paper proposes a novel model to determine occupancy density for outdoor events to prevent infectious disease transmission caused by the impossibility of proper dilution of human effluents in the atmosphere. It uses standardization processes to calculate natural ventilation air renewal and establishes theoretical occupancy based on activity and exhaled air percentage, aiming for indoor air quality comparable to the IDA2 standards. The study focuses on mass events in Mostoles (Spain), analyzing street activities and bullring events. It found that above a certain height in the open air, infection risk is low, eliminating capacity limitations. The resulting mathematical expressions can be adapted to different pathogens, ensuring the quality of indoor air conditions through capacity control. The process determines the ventilation required based on physical activity, considering both unrestricted and restricted situations. The relationship between required and available ventilation prevents disease transmission. The method’s effectiveness is demonstrated through comparisons between estimates and environmental measurements during Mostoles events. The maximum outdoor occupancy at ground level to achieve air quality comparable to the IDA2 standards is determined to be 2.36 persons/m2, while to prevent the transmission of SARS-CoV-2 it is determined to be 1.98 persons/m2. In addition, transmission will not occur during mass gatherings in locations over five meters above ground level. In conclusion, this model provides an adaptable tool to prevent the spread of infectious diseases at outdoor events by ensuring adequate air quality through occupancy control.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-02-21
DOI
https://doi.org/10.3390/buildings15050677
Citations
1
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
1.20

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Occupancy and Air Quality Model for Outdoor Events: A Strategy for Preventing Disease Transmission at Mass Events

Javier Álvarez, Álvaro Romero Barriuso, Blasa María Villena Escribano, Ángel Rodríguez Sáiz et al.
1 citations
Buildings
Indoor Air Quality and Microbial Exposure
1.20
article

Occupancy and Air Quality Model for Outdoor Events: A Strategy for Preventing Disease Transmission at Mass Events

Javier Álvarez, Álvaro Romero Barriuso, Blasa María Villena Escribano, Ángel Rodríguez Sáiz, Cristina González-Gaya
article en
1 citations

Abstract

This paper proposes a novel model to determine occupancy density for outdoor events to prevent infectious disease transmission caused by the impossibility of proper dilution of human effluents in the atmosphere. It uses standardization processes to calculate natural ventilation air renewal and establishes theoretical occupancy based on activity and exhaled air percentage, aiming for indoor air quality comparable to the IDA2 standards. The study focuses on mass events in Mostoles (Spain), analyzing street activities and bullring events. It found that above a certain height in the open air, infection risk is low, eliminating capacity limitations. The resulting mathematical expressions can be adapted to different pathogens, ensuring the quality of indoor air conditions through capacity control. The process determines the ventilation required based on physical activity, considering both unrestricted and restricted situations. The relationship between required and available ventilation prevents disease transmission. The method’s effectiveness is demonstrated through comparisons between estimates and environmental measurements during Mostoles events. The maximum outdoor occupancy at ground level to achieve air quality comparable to the IDA2 standards is determined to be 2.36 persons/m2, while to prevent the transmission of SARS-CoV-2 it is determined to be 1.98 persons/m2. In addition, transmission will not occur during mass gatherings in locations over five meters above ground level. In conclusion, this model provides an adaptable tool to prevent the spread of infectious diseases at outdoor events by ensuring adequate air quality through occupancy control.

BuildingsVol. 15(5)
Universidad Nacional de Educación a Distancia (ES), Universidad de Burgos (ES)
Comunidad de Madrid
Openalex Percentile: Top 25%
Indoor Air Quality and Microbial Exposure
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.