Efficiency Optimization of PMSM-Type Elevator Machine: An Industrial Comparison

This study presents the design, modeling, and prototyping of an external rotor permanent magnet synchronous motor (ER-PMSM) specifically for elevator traction systems. The external rotor design aims to surpass the efficiency of conventional inner rotor gearless elevator traction motors. A commercially available 4 kW inner rotor permanent magnet synchronous motor (IR-PMSM) was selected for comparative analysis. Critical parameters, including stator tooth tip thickness, slot tip radius, slot height, stator yoke height, stator tooth thickness, and the number of turns per phase, were optimized to enhance efficiency. The artificial bee colony (ABC) algorithm was utilized for the first time to determine the optimal configuration of an external rotor PMSM. The prototype was fabricated and subjected to rigorous testing using a dedicated electrical motor test setup. Comparative results demonstrated a significant improvement in efficiency for the ER-PMSM over the IR-PMSM, with the efficiency increasing from 72.5% to 84.67% at nominal operating conditions.

Authors

Institutions

Publication Details

Journal
Machines
Published
2025-02-21
DOI
https://doi.org/10.3390/machines13030173
Citations
1
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficiency Optimization of PMSM-Type Elevator Machine: An Industrial Comparison

Muhammed Salih Sarıkaya, Yusuf Avşar, Nurdogan Ceylan, Osman Eldoğan et al.
1 citations
Machines
Electric Motor Design and Analysis
0.73
article

Efficiency Optimization of PMSM-Type Elevator Machine: An Industrial Comparison

Muhammed Salih Sarıkaya, Yusuf Avşar, Nurdogan Ceylan, Osman Eldoğan, Ahmet Fenercıoğlu, Mücahit Soyaslan
article en
1 citations

Abstract

This study presents the design, modeling, and prototyping of an external rotor permanent magnet synchronous motor (ER-PMSM) specifically for elevator traction systems. The external rotor design aims to surpass the efficiency of conventional inner rotor gearless elevator traction motors. A commercially available 4 kW inner rotor permanent magnet synchronous motor (IR-PMSM) was selected for comparative analysis. Critical parameters, including stator tooth tip thickness, slot tip radius, slot height, stator yoke height, stator tooth thickness, and the number of turns per phase, were optimized to enhance efficiency. The artificial bee colony (ABC) algorithm was utilized for the first time to determine the optimal configuration of an external rotor PMSM. The prototype was fabricated and subjected to rigorous testing using a dedicated electrical motor test setup. Comparative results demonstrated a significant improvement in efficiency for the ER-PMSM over the IR-PMSM, with the efficiency increasing from 72.5% to 84.67% at nominal operating conditions.

MachinesVol. 13(3)
Sakarya University (TR), Bursa Technical University (TR), Samsun University (TR), Sakarya Uygulamalı Bilimler Üniversitesi
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, Sakarya Üniversitesi
Openalex Percentile: Top 31%
Electric Motor Design and Analysis
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.