Improved spectrometry of semi-insulating GaAs detectors by chemically thinning detector thickness

Abstract The spectrometric properties of a semiconductor detector depend on both, the base material quality and the electric collection field distribution. In the case of single pad semi-insulating (SI) bulk GaAs detectors with a circular electrode the electric field collecting the charge generated by the radiation is affected by electrode area, detector thickness and applied bias. Thinner and smaller detectors under higher bias obtain better spectrometric properties such as charge collection efficiency (CCE) and energy resolution (FWHM) due to a more intense electric collection field and fewer volume defects. However, the bulk SI GaAs substrate fabrication limits the lowest achievable wafer thickness to about 200 μm due to crystal fragility. We have developed the SI GaAs detectors of 60, 110, 155 and 200 μm thickness by wet chemical etching of 250 μm thick GaAs substrate. The samples were evaluated from point of view of electrical and spectrometric properties. The CCE and FWHM were evaluated with respect to detector thickness and applied bias. The highest achieved CCE increased with thinning detector material from 72% to 92%. The best energy resolution of about 80 keV for 5.5 MeV alpha particles was reached with the 60 μm thick detector.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-02-01
DOI
https://doi.org/10.1088/1748-0221/20/02/c02040
Primary Topic
Advanced Semiconductor Detectors and Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved spectrometry of semi-insulating GaAs detectors by chemically thinning detector thickness

Bohumír Zaťko, Dagmar Gregušová
Journal of Instrumentation
Advanced Semiconductor Detectors and Materials
article

Improved spectrometry of semi-insulating GaAs detectors by chemically thinning detector thickness

Bohumír Zaťko, Dagmar Gregušová
article en

Abstract

Abstract The spectrometric properties of a semiconductor detector depend on both, the base material quality and the electric collection field distribution. In the case of single pad semi-insulating (SI) bulk GaAs detectors with a circular electrode the electric field collecting the charge generated by the radiation is affected by electrode area, detector thickness and applied bias. Thinner and smaller detectors under higher bias obtain better spectrometric properties such as charge collection efficiency (CCE) and energy resolution (FWHM) due to a more intense electric collection field and fewer volume defects. However, the bulk SI GaAs substrate fabrication limits the lowest achievable wafer thickness to about 200 μm due to crystal fragility. We have developed the SI GaAs detectors of 60, 110, 155 and 200 μm thickness by wet chemical etching of 250 μm thick GaAs substrate. The samples were evaluated from point of view of electrical and spectrometric properties. The CCE and FWHM were evaluated with respect to detector thickness and applied bias. The highest achieved CCE increased with thinning detector material from 72% to 92%. The best energy resolution of about 80 keV for 5.5 MeV alpha particles was reached with the 60 μm thick detector.

Journal of InstrumentationVol. 20(02)
Slovak University of Technology in Bratislava (SK), Slovak Academy of Sciences (SK), Institute of Electrical Engineering of the Slovak Academy of Sciences (SK)
Openalex Percentile: Top 98%
Advanced Semiconductor Detectors and Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improved spectrometry of semi-insulating GaAs detectors by chemically thinning detector thickness — Bohumír Zaťko, Dagmar Gregušová · Journal of Instrumentation (2025) | TGRS Research Map | TGRS