Fast event-based electron counting for small-molecule structure determination by MicroED

Electron counting helped realize the resolution revolution in single-particle cryoEM and is now accelerating the determination of MicroED structures. Its advantages are best demonstrated by new direct electron detectors capable of fast (kilohertz) event-based electron counting (EBEC). This strategy minimizes the inaccuracies introduced by coincidence loss (CL) and promises rapid determination of accurate structures. We used the Direct Electron Apollo camera to leverage EBEC technology for MicroED data collection. Given its ability to count single electrons, the Apollo collects high-quality MicroED data from organic small-molecule crystals illuminated with incident electron beam flux densities as low as 0.01-0.045 e<sup>-</sup>/Å<sup>2</sup>/s. Under even the lowest flux density (0.01 e<sup>-</sup>/Å<sup>2</sup>/s) condition, fast EBEC data produced ab initio structures of a salen ligand (268 Da) and biotin (244 Da). Each structure was determined from a 100° wedge of data collected from a single crystal in as few as 50 s, with a delivered fluence of only ∼0.5 e<sup>-</sup>/Å<sup>2</sup>. Fast EBEC data collected with a fluence of 2.25 or 3.33 e<sup>-</sup>/Å<sup>2</sup> also facilitated a 1.5 Å structure of thiostrepton (1665 Da). While refinement of these structures appeared unaffected by CL, a CL adjustment applied to EBEC data further improved the distribution of intensities measured from the salen ligand and biotin crystals. However, CL adjustment only marginally improved the refinement of their corresponding structures, signaling the already high counting accuracy of detectors with counting rates in the kilohertz range. Overall, by delivering low-dose structure-worthy data, fast EBEC collection strategies open new possibilities for high-throughput MicroED.

Authors

Institutions

Publication Details

Journal
Acta Crystallographica Section C Structural Chemistry
Published
2025-02-21
DOI
https://doi.org/10.1107/s2053229624012300
Citations
6
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
4.54

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast event-based electron counting for small-molecule structure determination by MicroED

Duilio Cascio, Songrong Qu, Hosea M. Nelson, Logan S. Richards et al.
6 citations
Acta Crystallographica Section C Structural Chemistry
Mass Spectrometry Techniques and Applications
4.54
article

Fast event-based electron counting for small-molecule structure determination by MicroED

Duilio Cascio, Songrong Qu, Hosea M. Nelson, Logan S. Richards, Lygia S. de Moraes, Niko W. Vlahakis, José A. Rodríguez
article en
6 citations

Abstract

Electron counting helped realize the resolution revolution in single-particle cryoEM and is now accelerating the determination of MicroED structures. Its advantages are best demonstrated by new direct electron detectors capable of fast (kilohertz) event-based electron counting (EBEC). This strategy minimizes the inaccuracies introduced by coincidence loss (CL) and promises rapid determination of accurate structures. We used the Direct Electron Apollo camera to leverage EBEC technology for MicroED data collection. Given its ability to count single electrons, the Apollo collects high-quality MicroED data from organic small-molecule crystals illuminated with incident electron beam flux densities as low as 0.01-0.045 e<sup>-</sup>/Å<sup>2</sup>/s. Under even the lowest flux density (0.01 e<sup>-</sup>/Å<sup>2</sup>/s) condition, fast EBEC data produced ab initio structures of a salen ligand (268 Da) and biotin (244 Da). Each structure was determined from a 100° wedge of data collected from a single crystal in as few as 50 s, with a delivered fluence of only ∼0.5 e<sup>-</sup>/Å<sup>2</sup>. Fast EBEC data collected with a fluence of 2.25 or 3.33 e<sup>-</sup>/Å<sup>2</sup> also facilitated a 1.5 Å structure of thiostrepton (1665 Da). While refinement of these structures appeared unaffected by CL, a CL adjustment applied to EBEC data further improved the distribution of intensities measured from the salen ligand and biotin crystals. However, CL adjustment only marginally improved the refinement of their corresponding structures, signaling the already high counting accuracy of detectors with counting rates in the kilohertz range. Overall, by delivering low-dose structure-worthy data, fast EBEC collection strategies open new possibilities for high-throughput MicroED.

Acta Crystallographica Section C Structural ChemistryVol. 81(3)
California Institute of Technology (US), University of California, Los Angeles (US)
Howard Hughes Medical Institute, U.S. Department of Energy, California Institute of Technology, National Institutes of Health, National Institute of General Medical Sciences, Lawrence Berkeley National Laboratory
Openalex Percentile: Top 6%
Mass Spectrometry Techniques and Applications
4.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.